My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TILLIE LEWIS
>
1477
>
2800 - Aboveground Petroleum Storage Program
>
PR0523160
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 10:31:53 AM
Creation date
10/2/2018 11:28:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0523160
PE
2832
FACILITY_ID
FA0010602
FACILITY_NAME
WILLIAMS TANK LINES
STREET_NUMBER
1477
STREET_NAME
TILLIE LEWIS
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
16336003
CURRENT_STATUS
01
SITE_LOCATION
1477 TILLIE LEWIS DR
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
129
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V,__ _ t,. <br />San Joaquin County <br />Environmental Health Department IUL 1 1 2018 <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sj oq v^org/ehd ENVIRONMENTAL <br />Aboveground Petroleum Storage Act Inspection Repo <br />Facility Name: <br />Facility Address: Date: <br />WILLIAMS TANK LINES <br />1477 TILLIE LEWIS DR STOCKTON Aril 14 2015 <br />A ..,r,,.,..,.,s.. <br />.�. .. a'I'AT—'' <br />SUMMARY OF`VIOL'ATIONS <br />C ' 'Ss I CLASS 11, or MINOR - Notice to Comply) <br />Remarks <br />r613CFR <br />112.7(e) Failed to conduct inspections or maintain records for 3 years. <br />opies of the completed Tank, Piping, and Secondary Containment Inspection Checklist for 2013 were not found on <br />site. Inspections and tests must be conducted in accordance with the written procedures developed in the Spill <br />Prevention, Control, and Countermeasure (SPCC) Plan. Records of these inspections and tests must be signed by <br />the appropriate supervisor or inspector and kept on site with the SPCC Plan for a period of three years. Immediately <br />locate a copy of all inspection and testing records for the last three years, maintain them on site, and submit copies <br />to the EHD. <br />This is a Class II violation. <br />614 <br />CFR 112.7(f)(1) Failed to train personnel on discharge prevention. <br />Oil handling personnel were not trained. The training logs provided in the SPCC Plan are not being used (Personnel <br />Response Training Log and Discharge Prevention & Safety Meeting Log. At a minimum, oil handling personnel shall <br />be trained in the operation and maintenance of equipment to prevent discharges; discharge procedure protocols; <br />applicable pollution control laws, rules, and regulations; general facility operations; and the contents of the Spill <br />Prevention, Control, and Countermeasure Plan. Immediately provide this training to all oil handling personnel and <br />submit a copy of the training log to the END. <br />This is a Class II violation. <br />616 <br />CFR 112.7(f)(3) Failed to schedule and conduct discharge prevention briefings at least annually. <br />Discharge prevention briefings are not scheduled at least once a year. SPCC training was last conducted on July 27, <br />2010. Discharge prevention briefings for oil handling personnel must be scheduled and conducted at least once a year <br />to assure adequate understanding of the SPCC Plan for that facility. Such briefings must highlight and describe <br />known discharges or failures, malfunctioning components, and any recently developed precautionary measures. <br />Immediately schedule and conduct a discharge prevention briefing, ensure that they are scheduled and conducted at <br />least once a year. <br />This is a Class II violation. <br />713 <br />CFR 112.8(c)(6) Failed to perform scheduled tank tests and inspections by appropriately qualified personnel. <br />No integrity testing was observed for the petroleum tanks on site. Each aboveground container shall be tested and <br />inspected for integrity on a regular schedule and whenever repairs are made. The qualifications of personnel <br />performing tests and inspections, frequency and type of testing and inspections that take into account container size, <br />configuration, and design shall be determined in accordance with industry standards. Examples of these integrity <br />tests include, but are not limited to: visual inspection, hydrostatic testing, radiographic testing, ultrasonic testing, <br />acoustic emissions testing, or other systems of non-destructive testing. Comparison records and other records of <br />inspections and tests must be maintained on site. Immediately conduct the necessary testing and submit a copy of <br />the test results to the EHD, or provide equivalence as allowed by CFR 112.7(a)(2). <br />This is a Class II violation. <br />Received by <br />(initial): Ma(' <br />Inspector: a�pp <br />STACY RIVERA, Senior REHS <br />Phone: <br />(209) 468-3440 <br />Date: <br />04/14/2015 <br />Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.