Chevron Products Company 8 <br />Chevron Stanon N9-5775 301 W KcWtmin Lane LOCI] LA August 25 2000 <br />address the area of impacted soil, the contingency plan will involve evaluation of the <br />installation of additional SVE wells <br />The SVE system layout, including subsurface utilities, SVE wells, SVE piping, and SVE <br />equipment, including a 100-cfm catalytic oxidizer are shown on Figure 4 of G -R's Slte <br />Update The SVE wells and system equipment compound are shown on Figure 2 of G - <br />R's Site Update Permits associated with SVE system installation and discharge are <br />included in the Site Update A copy of G -R's Site Update has been included as <br />Attachment E Additionally, a copy of G -R's Reniediatroti System Plaits, approved by <br />the City of Lodi Building Department, showing system elevations and details is included <br />in Attachment F <br />Groundwater Extraction and Treatment <br />This GWE system proposed for the site consists of the existing interim GWE system, <br />consisting of extraction of groundwater by an electric submersible pump in well EX -1, <br />augmented by well MW -14 as additional extraction well Well MW -14 will be added to <br />the system by modifying the wellhead and installing a groundwater extraction pump <br />(piping was previously installed to well MW -14) <br />The CAO requires that the GWE system continuously operate, and Mr Marty Hartzell <br />• of the RWQCB has requested that wells MW- 13 and MW -14 not be utilized for <br />pumping at this time Howevei given the low extraction rates from well EX -1 and that <br />the MtBE plume has already reached the area of well MW -14, SECOR requests that the <br />RWQCB approve the following scopes of work <br />• Redevelopment of well EX -1 Fine-grained soil may have clogged a portion of <br />the well screen for this well reducing groundwater extraction flow rates <br />• Addition of well MW -14 to the interim GWE system Well MW -14 is located <br />within the MtBE plume and will be plumbed to the treatment system compound <br />• Evaluate the addition of MW -13 to the existing interum GWE system <br />Once well EX -1 has been redeveloped and well MW -14 is added to the system, ongoing <br />capture zone evaluation will be performed If the results of this ongoing evaluation fails <br />to show a capture zone large enough to contain the MtBE plume, the need for additional <br />extraction wells will be evaluated as a contingency plan Currently, the known extent of <br />the MtBE plume is approximately 250 feet away from the municipal well <br />The GWE system layout, including subsurface utilities, GWE well, GWE piping, and <br />GWE equipment, including three 2000 -pound carbon vessels, are shown on Figure 4 of <br />G -R's Site Update The GWE well and system equipment compound are shown on <br />Figure 2 of G -R's .Site Update Permits associated with GWE system installation and <br />. discharge are included in the Site t 1pdate A copy of G -R's .Stte Update has been <br />included. as Attachment E Additionally, a copy of G -R's Ilemedicrtioti .Systeni Plans, <br />077 41991 043/FRY <br />