0 <br /> MONITORING AND REPORTING PROGRAM NO.R5-2003-0838 -2- <br /> KEARNEY-NATIONAL,INC.AND ALPINE BUILDERS,INC. <br /> FORMER KEARNEY-KPF FACILITY <br /> SAN JOAQUIN COUNTY <br /> GROUNDWATER MONITORING <br /> As shown on Figure 1 and listed below,there are 45 wells. <br /> Shallow Zone Monitor Wells: B-1,B-4, B-5, KPS-5, KS-1, KS-2, KS-4, KS-5, KS-6,KS-8, <br /> SMW-1, SMW-2, SMW-3, SMW-4, SMW-5, SMW-6, <br /> TP-lA, TP-2A, and TP-3A <br /> Intermediate Zone Monitor Wells: KI-2, KI-3, KI4, KI-5,KI-6, KI-8, KI-11,KI-12, KI-13, <br /> KI-14, KI-16, KI-17, KEW-lU, KEW-2U, KEW-3U, <br /> KEW-41f,KPL-5, KPU-5, and PX-1 <br /> Deep Zone Monitor Wells: DMW-1, INJ-1, KD-1,KD-4, KD-5, and KD-6 <br /> Production Well: SPW <br /> The groundwater monitoring program for the 45 wells and any wells installed subsequent to the <br /> issuance of this MRP, shall follow the schedule in Table 1, unless the well is being used as an <br /> extraction or injection well, in which case sampling shall be in accordance with the extraction or <br /> injection well monitoring in MRP No. 5-01-269, Revision 2. The maximum detection limits for <br /> the constituents of concern are listed in Table 2. Once a well has been approved for <br /> abandonment, the monitoring requirements listed are no longer applicable. The volume of <br /> extracted groundwater shall be provided in semi-annual monitoring reports. Sample collection <br /> and analysis shall follow standard EPA protocol and the approved Water Quality Sampling and <br /> Analysis Plan. <br /> Prior to sampling,the groundwater elevations shall be measured in all wells. The Discharger <br /> shall obtain quantitative, stabilized field parameter measurements and purge a minimum of three <br /> casing volumes each time a well is sampled. Field parameters shall include pH, temperature, <br /> electrical conductivity, and turbidity. <br /> REPORTING <br /> When reporting data, the Discharger shall arrange the information in tabular form so that the <br /> date, the constituents, and the concentrations are readily discernible and in chronological order. <br /> The data shall be summarized in such a manner as to illustrate clearly the compliance with this <br /> MRP. <br /> As required by the California Business and Professions Code Sections 6735, 7835, and 7835.1, <br /> all reports shall be prepared by a registered professional or their subordinate and signed by the <br /> registered professional. <br /> Semi-annual reports shall be submitted to the Board by 1 February and 1 August of each year <br /> until such time as the Executive Officer determines that the reports are no longer necessary. <br /> Each semi-annual report shall include the following minimum information: <br /> a <br />