My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
610
>
2300 - Underground Storage Tank Program
>
PR0521866
>
COMPLIANCE INFO_2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2021 3:49:10 PM
Creation date
11/2/2018 5:12:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0521866
PE
2371
FACILITY_ID
FA0014852
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
610
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
04745039
CURRENT_STATUS
01
SITE_LOCATION
610 S Cherokee Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\C\CHEROKEE\612\PR0521866\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
11/1/2016 3:06:35 PM
QuestysRecordID
3247087
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEP 2 2 2016 <br /> ENVIRONMENTAL HEALTH <br /> DEPARTMENT <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑Professional Engineer <br /> ❑ Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum N Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used:Incon Sump Tester Equipment Resolution: +/-0.002" <br /> STP Sump 8 87 STP Sump tt 91 <br /> Sump Diameter: 42" 42" <br /> Sump Depth: 53" 53" <br /> Sump Material: Fiberglass Fiberglass <br /> Height from Tank Top to Top of 19" 19" <br /> Hi est Piping Penetration: <br /> Height from Tank Top to Lowest 21" 16" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Good Good I <br /> Portion of Sump Tested' 2"above piping 2"above piping <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes❑No ®NA ❑Yes El No ®NA <br /> roduct and water)? <br /> E <br /> Turbine shutdown response time N/A N/A <br /> Is system programmed ffail-safe <br /> shutdown?. ❑Yes or ❑No ®NA ❑Yes❑No ®NA <br /> II Was fail-safe verified to be ❑Yes❑No ®NA ❑Yes❑No ®NA <br /> q o erationalf <br /> j Wait time between applying <br /> pressure/vacuum/water and starling 30 minutes M minutes I <br /> test: ' <br /> Test Start Time: 12:10 pm 11:36 am <br /> Initial Reading(Rt): 5.9320 4.6578 <br /> Test End Time: 12:25 pm 11:51 am i <br /> Final Reading(RF): 5.9322 4.6568 I! <br /> Test Duration: 15 min. 15 min. <br /> f <br /> Change in Reading(Rr Rl): 0.0002 0.0010 <br /> Pass/Fail Threshold or Criteria: +1-0.002" +/-0.002" E <br /> Test Result: O Pass ❑Fail El Pass ❑Fail <br /> Was sensor removed for testing? ® Yes❑No❑NA ®Yes❑No❑NA <br /> Was sensor properly replaced and ®yes❑No❑NA ®Yes❑No❑NA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testing and recommended follow-up for failed rests) I <br /> "Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work". <br /> a <br /> 'If the entire depth of the sump isnot tested,specify how much was tested. If the answer to any of the questions indicated with an [ <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) i <br /> s <br /> 3 <br /> l <br />
The URL can be used to link to this page
Your browser does not support the video tag.