COMPLIANCE INFO 2010 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 6:07:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2010 - 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 6. PIPING 5U-W TESTING <br /> Test Method Developed BY: ❑Sump Manufacturer X Industry Standard ❑Professional Engineer <br /> L Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum X Hydrostatic <br /> n Other(Specify) <br /> Test Equipment Used:NOON Equipment Resolution:+4002 <br /> UST piping Sump Sump# Sump# 5ump# <br /> Sump Diameter: 42" <br /> Sump Depth: 527) <br /> Sump Material: Fiberglass <br /> Height from Tank Top to Top of 20" <br /> Hi hest Piping Penetration: <br /> Height from Tank Top to Lowest 20" <br /> Electrical Penetration_ <br /> Condition of sump prior to testing: good <br /> Portion of Sump Tested' 2"over pipe pen <br /> Does turbine shut down when <br /> sump sensor detects liquid(both Q Yes ❑No X NA ❑Yes ❑No ❑NA 0 yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> -product and water)?* <br /> Turbine shutdown response time N/A <br /> Is system programmed for fail-safe <br /> y p <br /> shutdown?' ❑Yes 11No X NA 11 Yes ❑No [1 NElEIL'A Yes No ❑NA Cl Yes No ❑NA <br /> Was fail-safe verified to be <br /> -operational?* ❑yes L-1NoNo X NA ❑Yes ❑No NA ❑Yes No ❑NA Yes No G NA <br /> Wait time between applying <br /> pressurelvacuum/water and starting 30 min <br /> test: <br /> Test Start Time: 10:52/11:08 - <br /> Initial Heading(Rj): 6.0574/6.0574 <br /> Test End Time: 11:07/11:23 <br /> Final Reading(RF): 6.0574/6.0573 <br /> Test Duration: 15 minX2 <br /> Change in Reading(RF-RI): 0.0000/0.0001 <br /> Pass/Faii Threshold or Criteria: +-0.002 <br /> Test Result: X Pass ❑Fail 0 Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? X Yes ❑No ❑NA C7 Yes ❑No ❑NA ❑Yes ❑No [INA ❑Yes E!No ❑NA <br /> Was sensor properly replaced and X yes ❑No ❑NA LJ Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> Coxnments— include information on repairs made pfior to testin , and recommended follow_I p for failed tests) <br /> 'If the entire depth of the sump is not tested, specify how much was tested. If the answer to my of the questions indicated with an <br /> asterisk M is"NO"or"NA",the entire sump must be tested, (See SWRCB LCT-160) <br />