• <br />6. PIPING SUMP TESTING <br />0 REC°D JUL 2 0 2015 <br />Test Method Developed By: ❑ Sump Manufacturer Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: [-]Pressure [] Vacuum DI Hydrostatic <br />❑ Other (Speci) <br />Test Equipment Used: See attached testing procedures _71Equipment Resolution: Inches <br />Sump # 87 <br />Sump # 91 <br />Sump # <br />Sump # <br />Sump Diameter: <br />48" <br />48" <br />Sump Depth: <br />66" <br />70" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />13" <br />12" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />27" <br />23" <br />Condition of sump prior to testing: <br />Fair <br />Fair <br />Portion of Sump Tested' <br />Above highest penetration <br />Above highest penetration <br />Above highest penetration <br />Above highest penetration <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?* <br />❑Yes ❑No ❑NA <br />[-]Yes ❑No [ZINA <br />❑ Yes❑ No ❑NA <br />[-]Yes ao ❑NA <br />Turbine shutdown response time <br />N/A <br />N/A <br />NIA <br />I N/A <br />Is system programmed for fail-safe <br />shutdown?` <br />No NA Yes❑ [:]NA []No NA Yes No NA <br />® []No No NA ❑Yes ❑❑� ❑ <br />Was fail-safe verified to be <br />operational?* <br />[:]Yes[:]No1❑NA <br />[:1 Yes El No SNA <br />[-]Yes❑No ❑NA <br />El Yes [:]No❑NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />15 minutes <br />15 minutes <br />15 minutes <br />15 minutes <br />Test Start Time: <br />11:57am <br />11:53am <br />Initial Reading (Rj): <br />0.73470 Inches <br />0.60952 Inches <br />Inches <br />Inches <br />Test End Time: <br />12:12pm <br />12:08pm <br />Final Reading (RF): <br />0.73537 Inches <br />0.60995 Inches <br />Inches <br />Inches <br />Test Duration: <br />15 mins <br />15 mins <br />15 mins <br />15 mins <br />Change in Reading (RF -RI): <br />0.00067 <br />0.00043 <br />Pass/Fail Threshold or Criteria: <br />.002 <br />.002 <br />Test Result: <br />El Pass ❑Fail <br />0Pass ❑Fail <br />❑Pass ❑Fail <br />❑Pass ❑Fail <br />Was sensor removed for testing? <br />[Z]Yes []No ❑NA <br />R]Yes [-]No ❑NA <br />❑ Yes ❑No [INA <br />❑ Yes [-]No [INA <br />Was sensor properly replaced and <br />verified functional after testing? <br />[Z]Yes ❑ ❑ No NA <br />i <br />Z Yes No NA <br />❑ ❑ <br />Yes No NA <br />❑ ❑ ® <br />Yes NoNA <br />❑ ❑ [-] <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />