0 10 RECD J U L 20 2015 <br />7. UNDER -DISPENSER CONTAINMENT ifl.lDO TESTING <br />Test Method Developed By: ❑ UDC Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Speer) <br />Test Equipment Used: See attached testing procedures Equipment Resolution: Inches <br />UDC # 1/2 <br />UDC # 3/4 <br />UDC # 516 <br />UDC # 718 <br />UBC Manufacturer: <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />31" <br />31" <br />31" <br />31" <br />Height front UDC Bottom to Top <br />of Highest Piping Penetration: <br />9„ <br />9„ <br />91' <br />91, <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />5" <br />5" <br />5" <br />s, <br />Condition of UDC prior to <br />testing: <br />Fair <br />Fair <br />Fair <br />Fair <br />Portion of UDC Tested <br />Above highest penetration <br />Above highest penetration <br />Above highest penetration <br />Above highest penetration <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />N/A <br />N/A <br />NPA <br />N/A <br />Turbine shutdown response time <br />NIA <br />NIA <br />NIA <br />NIA <br />Is system programmed for fail- <br />safe shutdown?` <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No 0 NA <br />❑ Yes ❑ No Z NA <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes ❑ No p NA <br />❑ Yes ❑ No p NA <br />❑ Yes ❑ No p NA <br />❑ Yes ❑ No p NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />15 minutes <br />15 minutes <br />15 minutes <br />15 minutes <br />Test Start Time: <br />1:41pm <br />1:40pm <br />2:03pm <br />2:03pm <br />Initial Reading (Rt): <br />2.38714 Inches <br />4.75232 Inches <br />4.42337 Inches <br />4.05375 Inches <br />Test End Time: <br />1:56pm <br />1:55pm <br />2:18pm <br />2:18pm <br />Final Reading (RF): <br />2.38809 Inches <br />4.75265 Inches <br />4.42348 Inches <br />4.05409 Inches <br />Test Duration: <br />15 mins <br />15 mins <br />15 mins <br />15 mins <br />Change in Reading (RF -Rt): <br />O.D0095 <br />0.00033 <br />0.00011 <br />0.00034 <br />Pass/Fail Threshold or Criteria: <br />.002 <br />.002 <br />.002 <br />.002 <br />Test Result: <br />9 Pass ❑ Fail <br />p Pass ❑ Fail <br />RI Pass ❑ Fail <br />p Pass ❑ Fail <br />Was sensor removed for testing? <br />❑ Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />p Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />❑ Yes ❑ No ❑ NA <br />p Yes ❑ No ❑ NA <br />© Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />