My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
7611
>
2300 - Underground Storage Tank Program
>
PR0231511
>
COMPLIANCE INFO 2005 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 9:18:35 AM
Creation date
11/2/2018 9:17:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2012
RECORD_ID
PR0231511
PE
2361
FACILITY_ID
FA0003695
FACILITY_NAME
ESTES TRUCKING
STREET_NUMBER
7611
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17705029
CURRENT_STATUS
01
SITE_LOCATION
7611 S AIRPORT WAY
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\7611\PR0231511\COMPLIANCE INFO 2005 - 2012.PDF
QuestysFileName
COMPLIANCE INFO 2005 - 2012
QuestysRecordDate
1/24/2018 7:33:04 PM
QuestysRecordID
3772154
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
173
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Nwa. .,Me <br /> SWRCB.January 2002 Page 4 of 7 <br /> Site: Estes Trucking <br /> 7611 S.Airport Way <br /> Stockton,CA 95205 <br /> Date: May 7,2007 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: [ ] Sump Manufacturer [X] Industry Standard [ ]Professional <br /> Engineer <br /> [ ]Other(Spec) <br /> Test Method Used: [ ] Pressure [ ]Vacuum [X] Hydrostatic <br /> [ ]Other(S eci)✓) <br /> Test Equipment Used: CALDWELL LEVEL GAUGE Equipment Resolution: 0.0025 <br /> Sump#1 <br /> Sump Diameter: 48 Inch <br /> Sump Depth: 36 Inch <br /> Sump Material: Fiberglass <br /> Height from Tank Top to Top of 30 Inch <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 20 Inch <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Dry <br /> Portion of Sump Tested 31 Inch <br /> Does turbine shut down when sump [ ]YES [ ]NO [ ]YES [ ]NO [ ]YES[ ]NO [ ]YES[ ]NO <br /> sensor detects liquid(both product& [X]NA [ ] NA [ INA [ INA <br /> water)? <br /> Turbine shutdown response time: <br /> Is system programmed for fail-safe [ ]YES [ ]NO I] YES[ ]NO []YES[ ]NO [ ]YES[ ]NO <br /> shutdown? [X]NA []NA [ INA [ INA <br /> Was fail-safe verified to be [ ]YES[ ]NO [ ]YES[ ]NO []YES[ ]NO [ ]YES[ ]NO <br /> operational? [X]NA [ INA [ INA [ INA <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 Minutes <br /> test: <br /> Test Start Time: 8:45 A.M. <br /> Initial Reading RI : _ 31 Inch <br /> Test End Time: 9:45 A.M. <br /> Final Reading 31 Inch <br /> Test Duration: 9:15 A.M. <br /> Chane in Reading(Rf-RI) 1/2 Hour <br /> Pass/Fail Threshold or Criteria: -0- <br /> Test Result: [X]PASS [ ] FAIL [ ] PASS [ ]FAIL [ ] PASS [ ] FAIL [ ]PASS[ IN <br /> Was sensor removed for testing? [X]YES [ ]NO [ ]YES t ]NO [ ]YES [ ]NO [ ]YES [ ]NO <br /> NA NA NA NA <br /> Was sensor properly replaced and IX]YES [ ]NO [ ]YES [ ]NO [ ]YES [ ]NO [ ]YES[ ]NO <br /> verified functional after testinl I [ ]N/A [ ]N/A [ ]N/A [ INA <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> 1 If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an asterisk(•)is "NO"or <br /> "NA",the entire sump must be tested. (S WRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.