Laserfiche WebLink
0 <br />r� <br />GILOARCO <br />Dispenser Interface M;odtt (DIM]. y VEEDER-ROOT <br />1. Verify that DIM installation kit corresponds with onsite Dispenser and POS equipment compatibility. <br />2. Printout and Archive Setup configuration <br />3. Verify Communication Slot is available. <br />4. If Communication Slot is available, remove power from TLS. <br />5. Install DIM and appropriate installation cables per the Dispenser Interface installation manual, 577013- <br />614 that is provided with DIM. <br />Remote verification <br />1. When work is completed, call FMS at 1-800-997-7725 option 4, option 1 (available 24 hours) <br />2. Inform FMS agent that you have just completed a Costco BIR Upgrade and that the FMS agent should <br />have some instructions to follow. <br />3. The FMS agent will run a startup which will verify remote dial out programming and import current site <br />setup. <br />4. After the startup is completed the FMS agent will program the TLS to dial out to verify that outbound <br />communications is successful. <br />5. The FMS agent will then compare the previous setup of the site to the current programming of the site. <br />Any setup parameters that do not match the site previous setup will be discussed with you as to why <br />they do not match and what action should be taken. <br />6. If the setup parameters match identically this process should not take any more than 10 or 15 minutes. <br />If multiple parameters need to be discussed the time will be extended. Please make sure TLS <br />programming matches the original as best as possible prior to calling FMS. <br />Gotcha's to watch out for <br />The current released software version does not allow sites with older 333.xx software to have <br />Maximum volume set above the Full Volume, reference chart below. For example if Full Volume is set at 19949 <br />and Max Volume is set at 19951, the Setup Data Warning will appear which will not clear on its own, until it is <br />corrected. This is considered a safety feature. The Overfill and High Product Alarm thresholds regarding <br />percentages are based off of the Max Volume entry. For installs that encounter this type of alarm, the Max <br />Volume needs to be changed to match the Full Volume <br />TANK 20 POINT FULL VOLUMES <br />TANK PRODUCT LABEL <br />GALLONS <br />GALLONS <br />1 Unleaded <br />19949 <br />19827 193.27 16607 <br />2 Unleaded <br />19949 <br />19767 19225 18477 <br />3 Premium <br />19867 <br />19710 19187 18453 <br />4 Additive <br />1514 <br />0 0 0 <br />TANK MAXIMUM VOLUME LIMIT <br />TANK PRODUCT LABEL <br />GALLONS <br />1 Unleaded <br />19951 <br />2 Unleaded <br />19951 <br />3 Premium <br />19951 <br />4 Additive <br />1514 <br />Veeder-Root Technical Su ort Contact Information. - <br />1 -800-323-1799 <br />