My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998 - 2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2300 - Underground Storage Tank Program
>
PR0231604
>
COMPLIANCE INFO_1998 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 3:20:17 PM
Creation date
11/5/2018 10:22:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998 - 2004
RECORD_ID
PR0231604
PE
2361
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0231604\COMPLIANCE INFO 1998 - 2004.PDF
QuestysFileName
COMPLIANCE INFO 1998 - 2004
QuestysRecordDate
11/29/2017 11:11:14 PM
QuestysRecordID
3738035
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page of <br /> 7. UNDER-DISPENSER CONTAINMENT TESTING <br /> Test Method Developed By: UDC Manufacturer Industry Standard Professional Engincer <br /> Other(Specify) <br /> Test Method Used: Pressure Vacuum Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> UDC#_7 UDC# UDC# UDC# <br /> UDC Manufacturer: _1041 C6 WJMx W <br /> UDC Material: H11114A <br /> UDC Depth: <br /> Height from UDC Bottom to Top <br /> of Highest Pi in Penetration: <br /> Height from UDC Bottom to - <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testin <br /> Portion of UDC Tested E {'tmwn ►afi5 <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both Yes No NA Yes No NA Yes No NA Yes No NA <br /> product and water)?' <br /> Turbine shutdown response time <br /> Is system programmed for fail- <br /> safe shutdown?' Yes No NA Yes No NA Yes No NA Yes No NA <br /> Was fail-safe verified to be Yes No NA Yes No NA Yes No NA Yes No NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: <br /> Initial ReadingR{ <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: <br /> Change in Reading(RF-R3): <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? Yes No NA Yes No NA Yes No NA Yes No NA <br /> Was sensor properly replaced and Yes No NA Yes No NA Yes No NA Yes No NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to�tlewft and recommended follow-up for failed tests) <br /> AIDC -jt ;4N 140-C 6E 1 6 ttquS� �I 1� S t o_( CNO LtI.- 1:i Cowt—ti <br /> 1 -`T+ 4 }� eo ++l <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to a�of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.