My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
816
>
2300 - Underground Storage Tank Program
>
PR0231470
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 2:09:29 PM
Creation date
11/5/2018 10:33:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231470
PE
2361
FACILITY_ID
FA0003911
FACILITY_NAME
VAN DE POL ENTERPRISES INC
STREET_NUMBER
816
Direction
E
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102010
CURRENT_STATUS
01
SITE_LOCATION
816 E FRONTAGE RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\816\PR0231470\COMPLIANCE INFO\2016 - PRESENT.PDF
QuestysFileName
2016 - PRESENT
QuestysRecordDate
9/22/2016 7:01:58 PM
QuestysRecordID
3006673
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
159
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sIgov.orglehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VAN DE POL ENTERPRISES INC 816 E FRONTAGE RD, RIPON January 19, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br /> The facility alarm logs did not document the following alarms, nor did the facility address how these alarms were <br /> addressed: <br /> L2 Disp 2 Fuel Alarm (UDC 314)on 2120117 <br /> T3(diesel tank)Overfill Alarm on 2121117 and 10/29/17 <br /> T1 (87 tank)Overfill Alarm on 511117 <br /> T3(diesel tank) Probe Out Alarm on 7130117, 7131117, and 8/7117 <br /> T2(91 tank)Overfill Alarm on 917117 <br /> These records shall be maintained on site for at least three years. Monitoring records include: (1)date and time of <br /> all monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3)results of any visual <br /> observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br /> reconciliations. Immediately locate and maintain the above mentioned alarm logs and submit copies to the EHD. <br /> This is a minor violation. <br /> 203 CCR 2712(b)Failure to maintain records of repairs, lining, and upgrades on site, for the life of the UST. <br /> Records of repairs, linings, and upgrades for the UST system were not found on site. These records shall be kept <br /> on site for the life of the tank. Immediately locate and maintain these records on site and submit copies to the EHD. <br /> This is a minor violation. <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. Immediately locate and retain a copy on site. <br /> Corrected on site. <br /> This is a repeat violation, Class II. <br /> 205 CCR 2712(i), 2634(e) Failure to submit a current UST Response Plan and have it available onsite. <br /> Failure to have a current UST Response Plan available on site.A copy of these plans shall be accessible on site at <br /> all times. Immediately locate and retain a copy on site. <br /> Corrected on site. <br /> This is a minor violation. <br /> FA0003911 PR023147C SC001 0111912018 <br /> EHD 23-01 Rev.09122116 Page 5 of 8 Underground Storage Tank Program CIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.