Laserfiche WebLink
C <br />For the top used on the 48" turbine encloo <br />sure, a 48" x 42" polyethylene adapter ring <br />is required. <br />If needed, refer to Section H for the optional <br />adhesive kit (to bond the turbine enclosure <br />to the containment collar) Sections 1, J, K <br />and L for the field installed fitting kits (for <br />electrical and plumbing connections to the <br />turbine enclosure). <br />G. Sealable Turbine Enclosure <br />(Model STE–B Series) The sealable turbine <br />enclosure is constructed of fiberglass rein- <br />forced plastic. The sealable turbine enclo- <br />sure is 42" or 48" diameter and can be <br />bonded to the appropriate secondary con- <br />tainment collar. The minimum length of the <br />sealable turbine enclosure is two feet and the <br />maximum is four feet: <br />Sealable Turbine <br />Model No. Enclosure Length <br />STE426 -2 2' <br />STE426 -3 31 <br />STE42B -4 4. <br />STE426 5 5 <br />STE48B -2 2 <br />STE48B -3 3' <br />STE4sB -4 4. <br />STE4813-5 51 <br />Cut lines for field trimming are marked on <br />the bottom 9 inches of the sealable turbine <br />enclosure at three inch increments. The top <br />and lid of the sealable turbine enclosure are <br />constructed of fiberglass reinforced plastic. <br />The oval lid opening (30" x 24") includes a <br />2" NPT threaded fitting (with steel fitting <br />plug) for access to the sealable turbine <br />enclosure without removing the lid. <br />Refer to Section H for optional adhesive kits <br />to bond the sealable turbine enclosure to the <br />FRP top and the secondary containment <br />collar; also refer to Section I for the optional <br />field installed fitting kit, and Section J for the <br />optional field installed electrical coupling kit <br />(Kit EC -1). <br />H.Turbine Enclosure Adhesive Kit (Kit -AD) <br />When properly installed and cured, the <br />adhesive kit provides a water tight seal to <br />prevent the ingress of water. The adhesive <br />kit includes In gallon of adhesive in a one <br />gallon capacity can.The kit also includes <br />catalyst (hardener), a wooden mixing stick, a <br />three inch wide plastic putty knife, 60 grit <br />sandpaper, and installation instructions. One <br />adhesive kit is required for each turbine <br />enclosure; the sealable turbine enclosure <br />requires two kits. <br />I. FRP Coupling Kit <br />(Kit FC -3 or FC -4) is designed to interface <br />with 3" or 4" nominal OD FRP pipe manu- <br />factured by Ameron or Smith Fiberglass. The <br />coupling ID is tapered at both ends. <br />The two-piece coupling is constructed of <br />fiberglass reinforced plastic and is field - <br />installed using the supplied adhesive. Both <br />pieces of the fitting are threaded together to <br />hold the fitting in position while the adhesive <br />cures. <br />Kit FC -3 or Kit FC -4 includes one 3" or 4" <br />nominal 1D FRP coupling, adhesive, catalyst <br />(hardener), plastic mixing stick and applica- <br />tor, 60 grit sandpaper, and installation <br />instructions. <br />The contractor must provide the hole saw <br />(41r2 or 51a inch OD) or reciprocating saw to <br />cut the hole in the turbine enclosure prior to <br />installing the FRP coupling. <br />90. Tank Lifting Lugs <br />Provide lifting lug(s) on all tanks. Lifting lug <br />system shall be capable of withstanding <br />weight of tank with a safety factor of 3:1. <br />J. Electrical Coupling Kit <br />Kit EC -1 is designed to interface with one <br />inch steel electrical conduit. The two-piece <br />coupling is constructed of steel and is field <br />installed using the supplied adhesive. Both <br />pieces of the fitting are threaded together to <br />hold the fitting in position while the adhesive <br />cures. <br />Kit EC -1 includes two one inch steel cou- <br />plings, adhesive catalyst (hardener), plastic <br />mixing stick, 60 grit sandpaper, and installa- <br />tion instructions. <br />The contractor must provide a two inch hole <br />saw or reciprocating saw to cut the hole in <br />the turbine enclosure prior to installing the <br />steel coupling. <br />K. Secondary Containment Collar <br />The secondary containment collar shall be <br />constructed of fiberglass reinforced plastic. <br />Collar shall be 42" or 48" in diameter and <br />will be factory -installed in accordance with <br />drawings. The collar will include a sensor <br />mounting bracket. <br />L. Containment Collar Sensor is pre - <br />assembled and ready to wire. All electrical <br />components must be U.L. listed or accept- <br />ed. This float switch sensor is capable of <br />detecting a 2" or more accumulation of liq- <br />uid (water or product) in the turbine enclo- <br />sure. <br />The float switch is constructed of Buna-N; <br />the float switch is housed in plastic casing <br />and includes a mounting clamp. <br />M. Ladders <br />Shall be standard carbon steel supplied by <br />the tank manufacturer. Refer todrawings for <br />location. <br />N. Heating Coils <br />Shall be standard item as manufactured <br />and/or supplied by the tank manufacturer <br />including 22" manway. <br />p. Probe Drawstring <br />Nylon line shall be 150 Ib. break strength <br />located at the monitoring fitting nearest the <br />end of the tank. When a reservoir is located <br />at this position, the drawstring shall be <br />installed within the reservoir. Drawstring <br />length will allow for a 7' tank burial depth. <br />Q. Fittings Threaded — NPT <br />1. All threaded fittings on U.L. labeled tanks <br />shall be located in a manway lid or a tank <br />mount within 12" of the tank top center line <br />and be constructed consistent with the <br />requirements of the U.L. label. Fittings to be <br />supplied with threaded cast iron plugs. <br />2. All standard threaded fittings to the prima- <br />ry tank and monitoring cavity are 4" in diame- <br />ter. The standard secondary containment cou- <br />pling is 6" in diameter. All standard threaded <br />fittings are half couplings. Reducers are to be <br />used for smaller sizes where specified and <br />provided by contractor. <br />3. Thread Standards — all threaded fittings <br />ehall have machine tolerances in accordance <br />with the ANSI standard for each fitting size. <br />4. Strength — Primary tank NPT fittings will <br />withstand a minimum of 150 foot-pounds of <br />torque and 1,000 foot-pounds of bending, <br />both with 2:1 factor of safety. <br />5. Sizes <br />Standard Reducer Sires <br />Inlet <br />4' <br />Outlet <br />4" <br />Vent <br />4' <br />Gauge <br />4` <br />Fill <br />4` <br />6. Location —Refer to drawings for location. <br />7. Suction Line — Shall be installed on site <br />by the contractor. Diameter of pipe and grade <br />and schedule as called out in other sections. <br />8. Return Line — Shall be installed on the <br />site by the contractor. Diameter of pipe and <br />grade and schedule as called out in other <br />sections. <br />9. All rigid internal piping shall be terminated <br />at least 4" from the bottom of the tank. <br />3.01, 3.02 Installation And Testing <br />Tanks shall be tested and installed according <br />to the current installation instructions provided <br />with the tank (refer to Fluid Containment Pub. <br />No. 6304 and include as part of your <br />specification). <br />27 <br />