Laserfiche WebLink
TANKNOLOGY <br /> Stage II Vapor Recovery Test Results Form <br /> Air/Liquid Ratio Test For Vacuum Assist Systems <br /> Site Information: 7-ELEVEN#32190 MARKET 4943 S. KINGSLEY(FRONTAGE RD) STOCKTON CA.95206 <br /> Work Order#: 2222221 Date: 05/14/2002 Technician: MICHAEL T LEVESQUE <br /> • <br /> Product Flow Rate Calculation lAir Volume Metered(ftA3) Ambient Conditions Corrected Final <br /> Gallons(g) Time(s) rate Initial Final Volume Pressure Temp. Air Volum Calculated A/L Ratio Results <br /> Nozzle# Product Dispensed Seconds G.P.M. Reading Reading Metered Inches Hg Degrees F (ft-3) A/L Average Pass/Fail <br /> 5 opw 27r PLUS 7.520 1 48.40 1 9.3 1 2780.65 2781.72 1.070 1.06 <br /> 1.06 Pass <br /> 7.510 <br /> 5 opw 27r PREMIUM 48.20 9.3 2781.72 27!±1.090 1.09 <br /> 1.09 Pass <br /> 3 opw 27r REG 7.497 48.38 9.3 2782.81 2783.83 1.020 1.02 <br /> 1.02 Pass <br /> 7.514 <br /> 3 opw 27r PLUS 48.15 9.4 2783.83 2784.86 1.030 1.03 <br /> 1.03 Pass <br /> 3 opw 27r PREMIUM • <br /> 7.508 47.50 9.5 2784.86 2785.88 1.020 1.02 <br /> 1.02 Pass <br /> Type of System Tested: Gilbarco Vapory <br />