My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:13 PM
Creation date
11/5/2018 8:25:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\COMPLIANCE INFO 2013 TO 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
232
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 1 of 2 <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC} TESTING <br /> Test Method Developed By: r' UDC Manufacturer r Industry Standard ( Professional Engineer <br /> r Other(Specify) <br /> Test Method Used By: r Pressure f Vacuum fo Hydrostatic <br /> r Other(Specify) <br /> Test Equipment Used: VPLT Equipment Resolution; 0.00001 in.f <br /> :UDC#1/2' ',UDC 93J4 UDC #5/6 UDC#7/8 <br /> uDC Manufacturer: gilba rco gilbarco I gilbarco gilbarco <br /> UDC Material: Fiberglass Fiberg lass Fiberg lass Fiberg lass <br /> UDC Depth: 35.00 35.00 35.00 35.00 <br /> _ f I <br /> Height From UDC Bottom to Tap of 1300 1300 1300 13.00 <br /> H . . . <br /> lghest Piping Penetration: f <br /> Height from UDC Bottom to Lowest 5.40 5.00 5.04 5.00 <br /> Electrical penetration: <br /> Condition of UDC prior to testing: good good good good <br /> Portion of UDC Tested' II, 15 15 15 15 <br /> Does turbine shut down when UDC <br /> sensor detects liquid(both product and r Yes r No r NA r Yes r No r NA r" Yes r" Nor NA rYes r Nor NA <br /> water)?' <br /> Turbine shutdown response time 00:00:00 sec 00:00:00 sec 00:00:00 sec 00:00:00 sec <br /> is system programmed for Fa Ci-safeI r Yes r Nor: NA r Yes r NO r NA r Yes r Nor: NA r Yes r Nor.- NA I <br /> shutdown?• <br /> Was fail-safe verified to beoperabonaf7* r Yes r No r NA r Yes r Nor NA r Yes r Nor NA r' Yes r Nor NA <br /> i <br /> Wadt time between applying $ min 5 min 5 min 5 min <br /> pressure/vacuum/water and starting test <br /> Test Start Time: i 15:26:00 15:25:00 15:26:00 15:30:04 <br /> tnlbal Reading(RI): 0.00000 in. 0.00000 in. 0.04000 in. 0.00000 In. <br /> Test End Time: 15:41:04 15:40:00 i 15:41:00 15:45;00 <br /> e <br /> Final Reading(Rr): -0.04054 In. -0.00060 In. 0.00010 In. -0.00010 In. <br /> r <br /> Test Duratlon. 15 min 15 min 15 min 15 min <br /> Change in Reading(RF-RI): -0.00050 In. -0.00060 in. 0.00014 In. -0.00010 In. I <br /> Pass/Fail Threshold or Criteria: +/-0.00200 +/-0.00200 +/-0.00200 +/-0.00200 i <br /> Test Result ,' a Pass Pass Pass Pass <br /> Was sensor removed for testing? I r Yes r No r' NA r Yes r Nor NA r Yes r?"- Nor NA G <br /> i Yes r'• Nor NA I <br /> Was <br /> sensor properly replaced and r Yes r Nor NA r Yes r Nor NA r Yes r Nor NA r Yes r No r, NA <br /> verified functional after testing <br /> I- ..........._..._��Y.._ _._..—.—_._.._.__) ..-------'--_._._..._...___.....__,.-..-_ .. .. .: .----_-. . .. ..... . ........... ........ _.__,_.__ <br /> Comments ?(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> _.___....,._..._...... <br /> t If the entire depth of the UDC Is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk(*) is?NO?or?NA?,the <br /> entire UDC must be tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.