My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 REPAIR
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2010 REPAIR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 4:17:01 PM
Creation date
11/6/2018 12:09:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 REPAIR
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\S\SAN JOAQUIN\345\PR0231867\REPAIR PLAN 2010.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
245
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
„ Ej FOOT VALVE (E) FILL <br /> EXTRACTOR (TYP. OF 2) <br /> (E) 1 "0 GALV. STEEL <br /> WATER DRAIN LINE TO <br /> CURB <br /> (N) SECONDARY <br /> CONTAINMENT TEST <br /> FITTING (TYP 2) 77 <br /> (E) SECONDARY PIPE (TO (E)TLS PROBE <br /> BE RE-USED AS CHASE <br /> PIPE; TYP 2) <br /> (E) 4"0 STEEL PIPE PLUG <br /> ------ (E) YO F.G. COMBINED VENT <br /> AND DAY TANK OVERFLOW RETURN <br /> 4"0 STEEL PIPE PLUG LINE IN 4"0 F.G. PIPE <br /> (E) #4 BARS AT 45' ANGLE (TO BE REPLACED IF SECONDARY <br /> 1 -1/2"0 F.O.S. AROUND MANHOLES, TYP. CONTAINMENT PIPING FAILS RE-TEST) <br /> AND N <br /> U U� <br /> LINE I <br /> (To BE <br /> GO NTA� _ST) <br /> WESTERN FIBERGLASS DOUBLE WALL <br /> CO-FLEX PIPING (TYP, OF 2) .3 <br /> SUMP PENETRATION <br /> SEE <br /> ------- OUTLINE OF (E) UNDERGROUND TANK <br /> 3A <br /> 5 TANK PLAN <br /> (N) 1 -1/2” DIA DOUBLEWALL WESTERN WESTERN' FIBERGLASS KATERIAI, LIST N.T.S. <br /> FIBERGLASS CO---FLEX PIPE (TYP 2) ITEM- NUMBE�R DESCRIPTION <br /> (E) BAS T WALL ------ -(EXTERIOR OF SUMP W <br /> ALL <br /> (E) T.C. ENVIROFLEX EXISTING 4" ROCKGUAR"' D <br /> (E) YO GALV, STE CARRIER PIPE SECONDARY PIPE P14500 1 -1/2' CO-FLEX PIPE <br /> (N) YO BLACK STEEL ION (TO BE REUSED AS CHASE PIPE) CONSULTANT STAMP ... <br /> (E) SUMP WALL, TYP. LIKIERIOR OF SUMP W <br /> (N) 1 -1/2"0 WESTERN FIRE. LASS CO--FLEX PIPE-- EXISTING PENETRATION <br /> (N) 2" x 1 - 1/2" WESTERN FIB R LASS ADAPTOR ---, EXISTING BOOT REDUCER <br /> AC8491UR REDUCER FITTING 4"0 -1/2 <br /> (N) 2 x 1 -1/2 BUSHING kQQTSIDF--QF MILDINO <br /> (N) 3 x 2 DOUBLE TAPPED BUSHING <br /> EXISTING 4" ROCKGUARD <br /> P14500 1-1/2- CO-FLEX PIPE <br /> '\-(E) ENVIROFLEX CURVED <br /> (E) TEST DONUT, BULKHEAD FITTING <br /> SLIDE BACK DOWN PIPE (INSIDE OF BQ"DING CONSULTANT STAMP <br /> (E) 1 -1/2"0 BLACK STEEL// AFTER TESTING AC8491UR ADAPTER —1-1/2"x2 <br /> FUEL SUCTION LINE TO // SALAS O'BRMN <br /> PUMP (TYP 2) ,----- -132 (N) CO-FLEX SECONDARY t[EST FITTING 1W ENGINEERS, INC. <br /> CONTAINMENT TEST FITTING (TYP 2) P11 101T <br /> C 1 -1/2- TEST ASSEMBLY 305 South 11th Street <br /> 0- San Jose, CA 95112--2218 <br /> .0 (N) 1 -1/2" LOCKABLE 436 14tb Street,, Suite 200 <br /> -5 USE ONLY URETHANE TEST BOOTS Oakland, CA 94612--2725 <br /> A. <br /> rr <br /> BALL VALVE (TYP 2) <br /> -i Street <br /> 498 Foam <br /> Monterey, CA 93940-1410 <br /> E (408) 282-1500 <br /> FAX: (408) 297--2995 <br /> www,salasobrien.coni <br /> 'EM ........ <br /> KXTION SYSI MATERIAL LIST <br /> 0 <br /> 0 REVISIONS / AUTHORIZATIONS <br /> �j) UL LISTED LOCKABLE ALL VALVE TO MATCH PIPE SIZE. <br /> NO. REAWNS / 41THORVAT06 By <br /> 0 <br /> (k�:F]C 0 N �F <br /> SECONDARY CONTAINMENT TEST FITTING. 80% ISSUED FOR CLIENT REVIEW 9/28/09 CSB <br /> SECONDARY StJPPLY PIPING TERMINATION TYP 2` t fd1JEL StJPPI..jY PIPING StJMP PENETRATION (TYP 2) <br /> E <br /> N.T.S. <br /> RESPONSE TO CLIENT COMMENTS 10/6/09 CSB <br /> 03 TEST ASSEMBLY, TEE WITH BUSHING TO 1/4" BALL VALVE, 1/4" QUICK <br /> .2 <br /> DISCONNECT, 1/4" QICK DISCONNECT CAP. 2 TRANSITION BOX ADDITION 10/13/09 CSB <br /> NOTE: REPLACE ALL U.G. VENT <br /> Oq PRIMARY AND SECONDARY PIPING IF 4 3 RESPONSE '10 CLIENT COMMENTS/ADD VENT LINE SCOPE 11/02/09 CSB <br /> SECONDARY CONTAINMENT TEST FAILS. <br /> 4 RESPONSE 10 COMMENTS (95%) 11/16/09 CSB <br /> (E) INTERIOR CUPA RESUBVITTAL 11/23/09 CSB <br /> BLDG. WALL <br /> E (E) EXTERIOR PROPRIETARY AT&T INFORMATION <br /> (N) 6"0" BLDG. WALL.._ NOT FOR GENERAL USE OR DISCLOSURE OUTSIDE OF AT&T <br /> THIS INFORMATION MAY ONLY BE USED BY AUTHORIZED <br /> REDUCING BOOT 4"0 F.G. PERSONNEL OF THE LOCAL GOVERNMENT AGENCY IN CONNECTION <br /> WITH APPLICATION FOR PERMITS AND AUTHORIZATIONS FOR <br /> 12 (TYP 2) ......... CONTAINMENT LIN (E) INTERIOR <br /> I BUILDINGS, CONSTRUCTION, AND/ OR ZONING CHANGES. <br /> 00 TOTAL CONTAINMENT <br /> N BLDG. WAL-1-- <br /> 0 -1�F <br /> M T WALL <br /> GA:1 _TE CA <br /> _V� <br /> 0 9 L <br /> BLACK TEE IG N <br /> IBE LA <br /> RN FIB <br /> (E) TEST <br /> SLIDE E <br /> AFTER <br /> ;A1Z'_1ONZ'1YZP Z1, :::N.T. <br /> 2 <br /> R3 <br /> (N) 4"0" LINE BOOT, TYP. DRAWINGS PREPARED FOR <br /> TEST BOOT (E) CABLE <br /> 0 <br /> 0 VAU I (E) 3" DIA TOTAL CONTAINMENT <br /> ET 3B <br /> SHE at&t CORPORATE <br /> FLEXIBLE SECONDARY (TO BE <br /> (N) FIRE BOX REUSED AS CHASE FOR NEW REAL ESTATE <br /> --- T <br /> -- <br /> FOR PIPING (E) CABLE DOUBLE WALL FLEXIBLE <br /> PROJECT TITLE: <br /> E -- <br /> ; ,� TRANSITION- VAULT SUPPLY PIPE) <br /> 0 3 MAX <br /> o <br /> v I STANDBY SYSTEM UPGRADES <br /> c <br /> 00 <br /> 345 N. SAN JOAQUIN STREET <br /> .......- ------ <br /> STOCKTON <br /> Z, <br /> 1rD <br /> CA <br /> us <br /> 0) PIN (N) YO E.G. VENT--- <br /> 9-8 FIREBOX M'" P SKTNCA01 <br /> 0-N TRANISTION (SEE ILS. LINE SLOPE UE--042 <br /> 6 DET LS; <br /> I d SHEET TITU: <br /> Z Cq SHEET F313) TO I-AN K UNDERGROUND FUEL�TANK <br /> I <br /> 1 -1/2"0 BLACK (N) WESTERN FIBERGLASS <br /> (N) YO WELDED BLACK .......... If Z3 ---- (E) YO GALV. STEEL--- 1 -1/2" DIA. CO--FLEX PIPING SUCTION SYSTEM <br /> (N) 6"0 STEEL STEEL PIPE <br /> IRON VENT LINE TO PIPE CARRIER PIPE MISCE EQU--SD.-F_,TAILS <br /> C H <br /> 5-- CHASE TO ROOF. �p AT&T PROJECT NUMBER: DATE: 9/21/09 SCALE: AS NOTED <br /> 7510405 DRAWN BY: NDP CHECKED BY: CSB <br /> TI AT&T AUTHORIZATION: <br /> SHEET: 3 OF: 4 SHEETS SH E No. <br /> (N) VENT PIPE PENETRA ON AT BUILDING N.T.S. Stantec Architecture Inc. Tel. 707.765.1660 <br /> 2) SUCTION PIPI PENETRATION AT -BU'11'-jDIN'G N.T.S. 1137 N. McDowell Blvd. Fox,707.765.9908 AL JEFFERSON AT&T DRAWING NO.: <br /> F:\Project\V, Perm�t\200783902843Adwq 11123 SKTN01 -01 -- 1jz& F3A <br /> -N-0- P\01_H\2007839028\DWCS\3_ /2009 !D148 AM Bro,�n, Chr,s Petaluma, CA U.S.A. 94954 www.stantec.corri <br /> ---------------- —---—---- ------------- ------- ....... —----- —------ <br />