My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
I
>
INDUSTRIAL
>
1010
>
2200 - Hazardous Waste Program
>
PR0518741
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2018 11:46:56 AM
Creation date
11/6/2018 8:39:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO_PRE 2019
FileName_PostFix
PRE 2019
RECORD_ID
PR0518741
PE
2228
FACILITY_ID
FA0010456
FACILITY_NAME
THATCHER COMPANY OF CALIFORNIA INC
STREET_NUMBER
1010
STREET_NAME
INDUSTRIAL
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
17728053
CURRENT_STATUS
01
SITE_LOCATION
1010 INDUSTRIAL DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\I\INDUSTRIAL\1010\PR0518741\COMPLIANCE INFO 1999 - 2016.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
943
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sierra Chemical Compan)* <br /> July 18, 2002 <br /> Page 2 <br /> D. Portable and stationary tanks shall be stored inside gas rooms or an enclosure with <br /> exhaust ventilation. CFC, 8002.2.1.2.1 <br /> E. Direct the exhaust ventilation to an exhaust system. CFC, 8003.1.3.5.1 <br /> F. The treatment system shall be utilized to handle the accidental release of gas. The <br /> treatment system shall be utilized to process all exhaust ventilation to be discharged <br /> from the gas room. CFC, 8003.3.1.3.5 <br /> G. Emergency power shall be provided in lieu of standby power for: <br /> 1) Exhaust ventilation, including the power supply for treatment systems <br /> 2) Gas detection systems <br /> 3) Emergency alarm systems <br /> 4) Temperature-control systems <br /> CFC 8001.10.3 and 8003.3.1.4 <br /> 5. A continuous gas-detection system shall be provided to detect the presence of gas at or <br /> below the permissible exposure limit. The detection system shall initiate a local alarm <br /> and transmit a signal to a constantly attended control station. The alarm shall be both <br /> visual and audible. CFC, 8003.3.1.6 <br /> 6. Gas rooms shall be internally sprinkerled. CFC, 8004.2.3.7.3 <br /> 7. The repair shop shall not be in the same room as the chlorine storage and transferring <br /> process. There must be a 2-hour occupancy separation between the chlorine <br /> transferring room (H-2 occupancy) and shop area (B occupancy). CFC, Table 36, <br /> Appendix VI-E <br /> Sampling Station <br /> 1. Provide approved storage of hazardous liquid waste under the sink. The open bucket <br /> capturing the waste liquids of reagent chemicals dumped down the open sink does not <br /> comply with the code as an approved container. The liquid waste chemicals shall have <br /> secondary containment. CFC. 8004.2.2. And 8001.4.2. <br /> 2. Repair the "OFF GAS' system that is leaking sodium hypochlorite solution into the <br /> secondary containment tank. The secondary containment tank is approximately 90% full. <br /> Remove all material from the secondary containment tank. CFC, 8003.1.3.3 <br /> 3. Secure the shelving and provide a lip on the shelving for storage of the one-gallon <br /> containers of reagent liquids. CFC, 8001.11.9 <br /> 4. Separate the reagent liquids that are not compatible. Separate the hypochlorites from <br /> the acids. CFC, 8001.11 <br /> 5. Shelving shall be of substantial construction, adequately braced and anchored. Shelves <br /> shall be provided with a lip or guard when used for storage of individual containers. CFC <br /> 8001.11.9 <br /> Chlorine Fill Line <br /> 1. Provide secondary containment around the fill line area. Chlorine liquid is spreading <br /> along the floor to storage area. Floors shall be liquid-tight with raised sills and a <br /> collection sump or system. CFC, 8004.1.4 <br /> 2. Post signs prohibiting smoking in dispensing areas or open use areas. CFC. 8004.1.8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.