Laserfiche WebLink
# • <br /> maintenance shop in the oil change bay. The tank is located against the south wall out of the <br /> way from traffic. <br /> Waste oil is pumped pneumatically from the oil change service pit inside the shop through a <br /> series of transfer hosing into the storage tank. There were no signs of defective hoses, pumps or <br /> other ancillary equipment associated with the tank system. According to Terry Smith, Fleet <br /> Maintenance Shop Manager, Evergreen removes approximately 200 gallons of waste oil per <br /> month for recycling. <br /> There were no obvious weld cracks, seam cracks, scraps of protective coating or signs of <br /> corrosion associated with the tank noted during the on site visual observations of the tank. There <br /> were no apparent oil stains indicative of leaks or overfilling of the tank. The tank, secondary <br /> containment, piping, pumps or other ancillary equipment were considered to be in good <br /> condition, and the immediate area to the tank was neat and orderly. There were no cracks noted <br /> with the concrete pavement supporting the tank. Refer to Photograph Log, Attachment A. <br /> The secondary containment system does not have an automated leak detection system; however, <br /> the tank is visually inspected daily and the inspections are documented accordingly. <br /> There was no sight `fill' gauge installed on the primary tank. <br /> The tank was not secured to the floor or to the wall. <br /> There were no emergency contact names and phone numbers posted on or near the tank. <br /> The following summary describes the findings of the tank assessment regarding the required <br /> components of a Waste Tank Assessment Report: <br /> (1)Design Standards <br /> There were no design standards available for review at the time of the site visit to assess <br /> the tank. However, subsequently Terry Smith contacted Mosier Brothers and obtained <br /> design specifications and pressure testing results. Refer to Attachment B, Mosier <br /> Brothers correspondence(4/27/2009). <br /> (2)Hazardous Characteristics of Waste Oil <br /> The tank is used to store used oil, which is a hazardous waste that is considered <br /> flammable under certain conditions, and may contain metals. The steel tank and the <br /> secondary containment system are compatible with hazardous characteristics of waste oil <br /> and metals. <br /> (3)Existing Corrosion Protection Measures <br /> The interior of the carbon steel tank is compatible with waste oil. The exterior surface of <br /> the tank was coated with a corrosion resistant industrial paint. The tank is located within <br /> liau+rAota Waste Oil Tank Assessment Report 1 NES.Inc. <br /> Waste Management,Inc.—Stockton Scavenger Facility NES Project Number 289.EC743.00 <br /> Stockton,California <br />