COMPLIANCE INFO_1994 - 1995
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_1994 - 1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 2:46:21 PM
Creation date
11/7/2018 10:11:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1994 - 1995
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\W\WEST\4040\PR0231963\COMPLIANCE INFO 1994 - 1995 .PDF
QuestysFileName
COMPLIANCE INFO 1994 - 1995
QuestysRecordDate
7/27/2018 4:40:09 PM
QuestysRecordID
3949296
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IV. MONITORING DOUBLE-WALLED TANKS: (CONTINUATION) <br /> It also contains an audible "BUZZER ALARM" to alert operators to a possible leak, <br /> a RED power Indicator Light, Each probe is connected to a separate Channel. <br /> The probes are Liquid Indicators detecting moisture at either the Annular Space <br /> or pipeline collection sump. <br /> 1 . When the system is operating normally, the GREEN Indicator Lights in <br /> Channels 1 ,2,3. and 4 (MODEL LA-04) and Channels 1 ,2,3,and 4 ( RONAN <br /> X76) will be lit. <br /> 2. If a leak is detected, the probe sensing the leak, will trigger a RED Liquid <br /> Indicator Light beneath the appropriate channel. The "BUZZER ALARM" will <br /> sound, and the RED Power Light will be lit. Investigate the alarm conditions <br /> by performing a circuit test. <br /> 3. To perform a circuit test, press the switch labeled LIQUID at the bottom left <br /> center of the panel. If operating properly, all of the Liquid Indicator Lights and <br /> the Power Indicator Light will be lit, and the Alarm will sound. If only one, or <br /> neither of the indicators respond, the system is malfunctioning, Immediately <br /> contact you service representative, <br /> 4. A circuit test will be performed weekly to confirm operational status of the <br /> LEAK ALERT System. A log will be maintained to document test performance <br /> and results. Also log instances of Alarm and actions taken. <br /> V. LEAK DETECTION RESPONSE PLAN: <br /> The following Leak Detection Response actions will be initiated when a leak is <br /> either suspected or confirmed. <br /> A. UNLEADED GASOLINE/DIESEL FUEL: <br /> 1 . A.leak will be suspected when a "BUZZER ALARM" sounds and a RED <br /> Liquid Indicator Light is lit in either of the channel indicators on the tank <br /> monitoring panel. <br /> 2. Investigate the alarm and contact the service representative to report the <br /> problem. Provide as much information as possible, i.e., Unit Serial <br /> Number, nature of problem, special circumstance, etc. Remove the tank <br /> from service pending confirmation of alarm condition. CONTACT THE <br /> CORPORATE ENVIRONMENTAL DEPARTMENT, <br /> 3. A leak will be confirmed as a result of investigation and test findings of <br /> the service representative, as to nature, extent and location of leak <br /> source, i.e., inner tank, outer tank, piping system, etc. Upon leak <br /> confirmation, CONTACT THE CORPORATE ENVIRONMENTAL <br /> CONSULTANT and take the following actions: <br /> -3- <br />