My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2132
>
2300 - Underground Storage Tank Program
>
PR0231669
>
COMPLIANCE INFO 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:19 PM
Creation date
11/8/2018 9:44:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016
RECORD_ID
PR0231669
PE
2361
FACILITY_ID
FA0001480
FACILITY_NAME
TESORO (MOBIL) 68222
STREET_NUMBER
2132
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17306035
CURRENT_STATUS
01
SITE_LOCATION
2132 MARIPOSA RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARIPOSA\2132\PR0231669\COMPLIANCE INFO\COMPLIANCE INFO 2016.PDF
QuestysFileName
COMPLIANCE INFO 2016
QuestysRecordDate
6/15/2017 6:48:05 PM
QuestysRecordID
3131588
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
u <br /> JUL 15 2016 <br /> 4. UNDER-DISPENSER CONTAINMENT(UDC)TESTIN <br /> Test Method Developed By: ❑ UDC Manufacturer ®industry Standard ❑ Professional ngineer <br /> ❑ Other(Spec) <br /> Test Method Used: ❑Pressure ❑ Vacuum ®Hydrostatic <br /> ❑ Other(Spec) <br /> Test Equipment Used: Ineon Sump Tester Equipment Resolution: +/-0.002" <br /> UDC#1/2 UDC#3/4 s UDC#5/6 UDC#7/8 <br /> UDC Manufacturer: Environ Environ Environ Environ <br /> UDC Material: Poly Poly Poly Poly <br /> UDC the 31" 31" 31" 31" <br /> Height from UDC Bottom to Top 6" 6" 6" 6" <br /> of Highest piping Penetration: <br /> Height from UDC Bottom to 4„ 4" 4" 4" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testis Good Good Good Good <br /> Portion of UDC Tested 2"above piping 2"above piping 2"above piping2"above i in <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes❑No ®NA ❑Yes❑No ®NA El Yes[I No ®NA E]Yes[3 No ®NA <br /> roduct and water)? <br /> ater?� <br /> Turbine shutdown response time N/A N/A N/A N/A <br /> Is system programmed for f til- <br /> safe shutdown?* ❑Yes❑No ®NA ❑Yes❑No ®NA ❑Yes❑No ®NA ❑Yes❑No ®NA <br /> Was fail-safe verified to be <br /> o emtional7* ❑Yes❑No ®NA 11Yes El No ONA ❑Yes❑No ONA ❑Yes No ONA <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test <br /> Test Start Time: 1:43 1:43 pin 1:43 pin 2:10 m <br /> Initial Readin (Ri): 7.8461 3.2430 19570 5.2201 <br /> Test End Time: 1:58 pro 1:58 vin 1:58 pin 2:25 pm <br /> Final Reading ): 7.8450 3.2427 1.9551 5.2209 <br /> Test Duration: 15 min. 15 min. 15 min. 15 min. <br /> Change in Reading RF-Pq : 0.0011 0.0003 0.0019 0.0008 <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002" +/-0.002" +/-0.002" <br /> Test Result: ® Pass ❑Fail ® Pass ❑Fail © Pass ❑Fail ® Pass ❑Fail <br /> Was sensor removed for testing? O Yes❑No❑NA ®Yes❑No Q NA ®Yes❑No❑NA M Yes Q No❑NA <br /> Was sensor properly replaced and <br /> verified functional after testing? O yes❑No❑NA O Yes❑No❑NA ®Yes E]No❑NA ®Yes ElNo[INA <br /> Comments—(include information on repairs made prior to testing and recommended ollow-up or ailed tests) <br /> "Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work". <br /> i If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is`NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.