My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2132
>
2300 - Underground Storage Tank Program
>
PR0231669
>
COMPLIANCE INFO 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:19 PM
Creation date
11/8/2018 9:44:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016
RECORD_ID
PR0231669
PE
2361
FACILITY_ID
FA0001480
FACILITY_NAME
TESORO (MOBIL) 68222
STREET_NUMBER
2132
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17306035
CURRENT_STATUS
01
SITE_LOCATION
2132 MARIPOSA RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARIPOSA\2132\PR0231669\COMPLIANCE INFO\COMPLIANCE INFO 2016.PDF
QuestysFileName
COMPLIANCE INFO 2016
QuestysRecordDate
6/15/2017 6:48:05 PM
QuestysRecordID
3131588
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
\J <br /> L��.k�..: 1► �: -.. <br /> JUL 15W6 <br /> 5. UNDER-DISPENSER CONTAINMENT UDC TESTING ` � IT <br /> Test Method Developed By: ❑ UDC Manufacturer ®Industry Standard ❑ Professional Engineer <br /> ❑ Other(Spec) <br /> Test Method Used: ❑Pressure ❑ Vacuum ®Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: Incon Sump Tester Equipment Resolution: +/_0.002" <br /> UDC#9/10 UDC#11/12 UDC#13/14 <br /> UDC Manufacturer: Environ Environ Environ <br /> UDC Material: Pol Poly Poi <br /> UDC the 31" 31" 31" <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: 6" 6" 6" <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: 4" 4" 4" <br /> Condition of UDC prior to Good Good <br /> testing: Good <br /> Portion of UDC Tested 2"above piping 2"above viving 2"above piping <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes❑No R NA ❑Yes❑No ®NA ❑Yes❑No ®NA <br /> roduct and water)? <br /> Turbine shutdown response time N/A N/A N/A <br /> Is system programmed for fail- <br /> safe shutdown?o ❑yes❑ C1No RNA ❑Yes❑No ®NA Yes❑No ®NA <br /> Was fail-safe verified to be <br /> operational?* [I❑Yes❑No ®NA ❑Yes❑No ®NA Yes[3No ONA <br /> Wait time between applying <br /> Pressure/vacuum/water and 30 minutes 30 minutes 30 minutes <br /> starting test <br /> Test Start Time: g2:25 <br /> WNo <br /> m 2:38 m <br /> Initial Reading(R, : 6318 1.6268 <br /> Test End Time: m m 2:54 proFinal Readin Rr : 1319 1.6251 <br /> Test Duration: n. in. 16 min. <br /> Chane in Readin Rr-Rt): 5001 0.0017 <br /> Pass/Fail Threshold or Criteria: 2" .002" +/_0.002Test Result: ❑F ❑Fail E7 Pass ❑Fail <br /> Was sensor removed for testin ? ❑ No❑NA ®Yeso❑NA <br /> Was sensor properly replaced and ❑ No❑NA ®Yes❑No❑NA <br /> verified functional after testin ? <br /> COMMent9—(include information on repairs made prior to testing, and recommended ollow up for failed tests) <br /> Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work". R <br /> F <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />