My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MYRTLE
>
2849
>
2300 - Underground Storage Tank Program
>
PR0538822
>
COMPLIANCE INFO 2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 3:43:54 PM
Creation date
11/8/2018 9:46:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0538822
PE
2351
FACILITY_ID
FA0022301
FACILITY_NAME
Regional Transportation Center
STREET_NUMBER
2849
Direction
E
STREET_NAME
MYRTLE
STREET_TYPE
St
City
Stockton
Zip
95205
APN
157-020-11
CURRENT_STATUS
01
SITE_LOCATION
2849 E Myrtle St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MYRTLE\2849\PR0538822\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
4/13/2018 5:10:16 PM
QuestysRecordID
3060171
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
787
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank Program Inspection Report <br />Date: <br />September 25, 2017 <br />Facility Address: <br />2849 E Myrtle St, Stockton <br />Facility Name: <br />Regional Transportation Center <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California95205-6232 <br />Telephone:(209) 468-3420 Fax :(209) 468-3433 Web:www.sjgov.org/ehd <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Q2 (diesel 2) 10/6/16 (two times), 6/20/17 gross line fails <br />Q2 9/30/16 cont handle alm <br />Q3 (gasoline) 1/29/17 grs test needed alm <br />S1 (DT-1 product) 12/20/17 sensor fault alarm <br />S1 1/3/17, 1/9/17, 5/18/17, 5/19/17, 8/1/17 no vacuum <br />S1 2/15/17 vacuum warning <br />S2 (DT-2 siphon) 2/15/17 (two times), 5/18/17 no vacuum <br />S2 2/15/17 high liquid <br />S3 (DT-1 vent) 1/9/17, 5/19/17, 5/22/17, 8/1/17 no vacuum <br />S4 (DT-2 product) 2/15/17, 2/21/17 vacuum warning <br />S4 2/21/17 no vacuum <br />S5 (DT-2 vent) 2/15/17, 5/1/8/17 no vacuum <br />S5 2/15/17 high liquid <br />S6 (gasoline product) 2/15/17 no vacuum <br />S6 2/15/17 high liquid <br />S7 (gasoline vent) 2/15/17 no vacuum <br />S7 2/15/17 high liquid <br />S8 (gasoline vapor) 2/8/17, 2/15/17 no vacuum <br />S8 2/15/17 high liquid <br />During the monthly inspection, the designated operator shall review the alarm history for the previous month, check <br />that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br />documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br />monthly inspections at this facility are including all of the required information on the reports. <br />This is a repeat violation, Class II. <br />301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills. <br />The fuel filters in UDCs NR-1 and NR-2 are not contained within the secondary containment (under dispenser <br />containments) for the dispenser piping. The underground storage tank system shall be operated to prevent <br />unauthorized releases. Immediately make all necessary alterations to provide secondary containment or meet all <br />applicable Title 23 requirements for a UST system, under permit and inspection of the EHD. <br />This is a Class II violation. <br />Page 6 of 9
The URL can be used to link to this page
Your browser does not support the video tag.