My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:14 PM
Creation date
11/8/2018 9:50:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\4855\PR0506650\COMPLIANCE INFO 2016-PRESENT .PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
249
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCH ARCO AM PM* 4855 S HWY 99 FRONTAGE RD, STOCKTON February 14, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to document all the alarms from the attached alarm history on the 1//11/17, 11/28/16, <br /> and 4/29/16 designated operator monthly inspection report and failed to check that they were responded to <br /> appropriately. The missing alarms include: T1 Overfill alarms on 11/14/16, 11/24/16, and 1/3/17; T3 High water <br /> alarm on 3/23/16; and the L13: 89 fill piping sump fuel alarm on 3/5/16. During the monthly inspection, the <br /> designated operator shall review the alarm history for the previous month, check that each alarm was documented <br /> and responded to appropriately, and attach a copy of the alarm history with documentation taken in response to any <br /> alarms to the monthly report. Ensure that designated operators performing monthly inspections at this facility are <br /> including all of the required information on the reports. <br /> he designated operator listed 2/16/16 instead of 2/8/16 for the monitoring system certification, spill container, and <br /> leak detector testing on the 4/29/16 monthly inspection report. During the monthly inspection, the designated <br /> operator shall check that all required testing and maintenance for the UST system have been completed and <br /> document the dates they were done. Ensure that designated operators performing monthly inspections at this <br /> facility are including all of the required information on the reports. <br /> The designated operator failed to include the dates on the panel printouts for 5/5/16 and 8/2/16 designated operator <br /> monthly inspection reports. Ensure that designated operators include the dates on the panel printouts. <br /> This is a repeat violation, Class ll. <br /> 211 CCR 2715(f) Designated operator employee training not performed or log not kept. <br /> The designated operator employee training did not include the Hire Date on the list of employees trained by the <br /> designated operator. The designated operator shall train facility employees for which he or she is responsible in the <br /> proper operation and maintenance of the UST system once every 12 months. The training shall include, but is not <br /> limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br /> the training records to the EHD. <br /> This is a minor violation. <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The 323 sensor was found to be in leaning over in under dispenser containment(UDC) 9-10. All monitoring <br /> equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. The service <br /> technician placed the 323 sensor in an upright position after testing the sensor. Ensure that the 323 sensors are <br /> placed vertically in the UDCs. This was corrected onsite. <br /> This is a repeat violation, Class ll. <br /> FA0007571 PRO506650 SCO01 02/14/2017 <br /> EHD 23-01 Rev.09/22/16 Page 5 of 7 Underground Storage Tank Program OR <br />
The URL can be used to link to this page
Your browser does not support the video tag.