My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
8606
>
2300 - Underground Storage Tank Program
>
PR0232261
>
COMPLIANCE INFO 2007 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:19:49 PM
Creation date
11/8/2018 9:54:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2010
RECORD_ID
PR0232261
PE
2361
FACILITY_ID
FA0002590
FACILITY_NAME
THORNTON 76
STREET_NUMBER
8606
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
07242019
CURRENT_STATUS
01
SITE_LOCATION
8606 THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\THORNTON\8606\PR0232261\COMPLIANCE INFO 2007 - 2010.PDF
QuestysFileName
COMPLIANCE INFO 2007 - 2010
QuestysRecordDate
2/27/2018 5:13:36 PM
QuestysRecordID
3808429
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />SWRCB, January 2002 <br />6. PIPING SUMP TESTING <br />• 'i <br />Page 4 of -( <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard X Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />0 Other (Spec) <br />Test Equipment Used: Caldwell Level Change Indicator <br />Equipment Resolution: .002 <br />.# . <br />Sump # 1 <br />Sump # 2 <br />Sump # 3 <br />Sump <br />Sump Diameter: 42" <br />42" <br />42" <br />Sump Depth: 42" <br />42" <br />44" <br />Sump Material: Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of Vapor 15" <br />Vapor 15" <br />Vapor 15" <br />Highest Pi mg Penetration: Product 13" <br />Product 13" <br />Product 12" <br />Height from Tank Top to Lowest 711 <br />8" <br />6" <br />Electrical Penetration: <br />Condition of sump prior to testing: Dry <br />Dry <br />Dry <br />Portion of Sump Tested' Water Line 22" <br />Water Line 22" <br />Water Line 23" <br />Does turbine shut down when <br />sump sensor detects liquid (both X Yes ❑ No ❑ NA <br />X Yes ❑ No 0 NA <br />X Yes ❑ No ❑ NA <br />0 Yes ❑ No ❑ NA <br />product and water)?* <br />Turbine shutdown response time Not Alarmed <br />Not Alarmed <br />Not Alarmed <br />Is system programmed for fail-safe X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />❑Yes ❑ No [INA <br />shutdown? <br />Was fail-safe verified to be Yes X No 0 NA <br />Yes X No ❑ NA <br />Yes X No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />operational?* <br />Wait time between applying water 5 Minutes <br />5 Minutes <br />5 Minutes <br />and starting test: <br />Test Start Time: 9:40 <br />8:55 <br />9:00 <br />Initial Reading (Rj): .001 <br />.001 <br />.001 <br />Test End Time: 10:10 <br />9:25 <br />9:30 <br />Final Reading (RF): .001 <br />.001. <br />.001 <br />Test Duration: 30 Minutes <br />30 Minutes <br />30 Minutes <br />Change in Reading (RF -R,): 0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: .005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />Test Result: X Pass ❑ Fail <br />X Pass ❑ Fail <br />X Pass 0 Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes 0 No ❑ NA <br />❑ Yes ❑ No [INA <br />Was sensor properly replaced and X Yes ❑ No ❑ NA <br />X Yes 0 No ❑ NA <br />X Yes ❑ No ❑ NA <br />❑ Yes ❑ No DNA <br />verified functional after testin ? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to a_y of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.