COMPLIANCE INFO 2012-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
COMPLIANCE INFO 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:19:01 PM
Creation date
11/8/2018 9:55:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRACY\3775\PR0231418\COMPLIANCE INFO\COMPLIANCE INFO 2012-2015.PDF
QuestysFileName
COMPLIANCE INFO 2012-2015
QuestysRecordDate
10/10/2017 8:57:48 PM
QuestysRecordID
3096410
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STEP 20: CUTTING LOWER END OF DROP STEP 24: CHECK INSTALLATION <br /> TUBE Insert the drop tube all the way into the tank until TOOLS NEEDED FOR INSTALLATION Install the MIF 4"X4" riser adapter using the <br /> Measuring from the underside of the inlet tube the flange and gasket seat onto the top of the AND ASSEMBLY: See Photo below. MIF 4X4 Installation Instructions onto the <br /> flange, mark the overall length of the drop tube a Phil-Tite MIF 4 X 4 Riser Adaptor. 1. 3/"X20' Ta top of the 4" inch tank riser and correctly <br /> ( ) <br /> distance of B minus 6" inches or as per local Ptdl-lite cast ion tour pe measure torque the adapter using the Phil-Tice <br /> codes or requirements. Determine dimension (B) Dustcarvit 003 seal 2. High-Tension Hacksaw, with fine tooth special tool adaptor (T-7102 Orange). <br /> from the DropTube Measurement Worksheet fin.gadep r,..,,a,:d <br /> (24-32 teeth/inch) blade or equivalent. <br /> taken in Step 3, Figure 1 (Top of the FFS MIF 4 X IMPORTANT3. Fine teeth half round file or de-burring <br /> 4 Riser Adaptor to the bottom of the tank). �� g <br /> any sharp <br /> Saw/Cut off the excess tube and fife off f ' ' tool Fit the Fill Spill Container Assembly <br /> _ __- �:` <br /> 4. Phil-Tite Flaring Tool Assy. (T-6100-FT) <br /> burrs. �.,,w.1, Install the fill spill container onto the MIF <br /> 5 Y4" Ratchet with 3" extension 4"X4" riser adaptor that is installed onto the <br /> Optional: Install the Phil-cite Tank Bottom ,14•Flat3czt ��___ •$•���°'�"�° <br /> Protector on the lower tube (Refer to Installation �— °"'' '' " s' 4" inch riser #o tank to Measure the <br /> >:.>. 6. 3116 X114 & 5116 X114 Hex with socket p <br /> ",<=y distance from the to of the spill container <br /> instructions supplied with the Tank Bottom E•`�°"•'" _Dra'ma&x adaptor p p� <br /> Protector). pp .4 thatsPa, 7. Small common screwdriver to finish grade (approximately 4 Y2" inches <br /> for 85000 series spill container and 1 %" <br /> Drop tube5eal ,_- —�Topflange ordroptube 8. Fine Tip Marking pen (Sharpie) or pencil <br /> STEP 21: PREPARE TANK RISER FOR inches for 85000-1 series spill container). <br /> � �- -- <br /> OVERFILL VALVE INSERTIONht1F04?JwAdapta e� <br /> ] This is to verify the 4si inch riser to the tank <br /> *� <br /> 4.11�readadtan,ksisahas been cut to the appropriate length. (See <br /> IMPORTANT: Inspect the tank riser pipe for any _ f- diagram below) <br /> foreign.material, Over spray from tank relining or <br /> any internal burrs inside of pipe must be removed Topc(staagetanf a. <br /> prior to installation. Failure to have an ' Q t. <br /> unobstructed tank riser pipe may prevent proper Umrdtoptube and akrtdmkerbedyfa<Aw O <br /> installation or operation of the valve. Thoroughly 4aembledandteftedtoCARBTP20),ID <br /> clean top of tank riser pipe. <br /> rswsr,t,tarYanre. .. - -. <br /> Important: Before installing the drop tube, <br /> allow the sealant to cure for minimum of 4 WeldedatrNhtbottom wbe �® <br /> hours. - o o Thfeadonboitornd{op Spill Collector <br /> Bottom drop tube should be <br /> STEP 22: REMOVE ELASTIC BAN© — — <br /> Dtstancetobe6'(orasper(ocalr � ents)— ang3e WARNING drop Tube <br /> Check the exposed floats for freedom of kem .,_ <br /> movement. If floats drag, inspect guide bar for Using electrically operated equipment near crop Tube — M/F 4x4 <br /> damage. Both of the floats should be free to move Figure 3 gasoline or gasoline vapors may result in Gasket Adaptor <br /> up and down without drag. STEP 25: FINAL INSTALLATION fire or explosion, causing personal injury Tank <br /> and property damage. Check to assure the --- Riser <br /> STEP 23: INSTALL THE DROP TUBE Install a Phil-Tite Fill Spill Container according to working area is free from such hazards, and _ <br /> Make sure the special drop tube seal (85039-DT) the manufacturer's installation instructions. always use proper precautions. <br /> is installed correctly. Slowly insert the drop tube Ensure that the drop tube does not rotate while <br /> into the tank riser pipe. Do not force the valve tightening the Spill Container by observing the Auto Limiter II -- Drop Tube <br /> into the tank riser pipe. If any obstruction or position of the deflector. Install a Phil-Tite Preassemble Instructions <br /> foreign matter interferes with smooth insertion of rotatable swivel adaptor and tighten according to A change in the fill riser length after <br /> the valve, the tank riser pipe must be cleared. the manufacturer's installation instructions. Tank Riser 4" inch cutting the drop tube could affect the <br /> Install the previously measured, cut and operation of the mechanical overfill <br /> threaded fill riser into the tank fill opening <br /> WARNING using the spill container installation valve. <br /> Failure to follow the assembly and installation instructions. Apply pipe dope to the riser To determine the correct lengths to cut <br /> instructions or use of excessive force to insert: NPT male threads. Pipe dope is to be non- the upper and lower sections of the drop <br /> the Auto Limiter II® will " VOID THE hardening, gasoline resistant pipe thread tube for installation; use the Work Sheet <br /> WARRANTY!" seal compound. for Determining the Drop Tube Lengths <br /> Correctly torque the tank riser to ensure a that follows: <br /> vapor and liquid tight fit. <br /> 10 3 <br />