My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
COMPLIANCE INFO 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:19:01 PM
Creation date
11/8/2018 9:55:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRACY\3775\PR0231418\COMPLIANCE INFO\COMPLIANCE INFO 2012-2015.PDF
QuestysFileName
COMPLIANCE INFO 2012-2015
QuestysRecordDate
10/10/2017 8:57:48 PM
QuestysRecordID
3096410
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 7 of 9 <br /> 8. FELL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑ Other(Spec) <br /> Test Method Used: ❑Pressure ❑vacuum N Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: <br /> Fill Sump#87 Fill Sump#89 Fill Sump #91 Fill Sump# <br /> Sump Diameter: 48" 48" 48" <br /> Sump Depth: 73" 72" 70" <br /> Height from Tank Tap to Top of 25" 25" 24" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 32" 30" 31" <br /> Electrical Penetration: <br /> Condition of sump prior to Fair Fair Fair <br /> testing: <br /> Portion of Sump Tested Above highest Above highest Above highest Above highest <br /> penetration penetration nenetration penetration <br /> Sump Material&Manufacturer: Fiberglass Fiberglass Fiber lass <br /> Wait time between applying <br /> pressure/vacuum/waterand 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: 12:08pm 11:16am 10:46am <br /> Initial Reading(RI): 3.5585 1.3326 4.5509 <br /> Test End Time: 12:23pm 11:31am 11:01am <br /> Final Reading(RF): 3.5590 1.3325 4.5507 <br /> Test Duration: 15 min 15 min 15 min 15 min <br /> Change in Reading(R,-R,): 0.00043 0.00010 0.00028 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Re ® Pass ❑ Fail 0 Pass ❑ Fail Z Pass ❑Fail ❑ Pass ❑Fail <br /> Is there a sensor in the sump? N Yes ❑ No ® Yes ❑ No N Yes ❑ No N Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is ❑Yes ❑No ENA ❑Yes❑No NNA []Yes[:]No ENA ❑Yes❑No NNA <br /> detected? <br /> Was sensor removed for testing? ®yes ❑No ❑NA ®YesYes [:]No ❑ Yes No <br /> ❑No❑NA NA NA <br /> Was sensor properly replaced and SYes ❑No ❑NA ®Yes ❑No[INA ®Yes ❑No❑NA NYes [:]No❑NA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />