My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
6732
>
2300 - Underground Storage Tank Program
>
PR0231830
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:38:43 PM
Creation date
11/8/2018 9:59:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0231830
PE
2361
FACILITY_ID
FA0004030
FACILITY_NAME
THREE PALMS GROCERY
STREET_NUMBER
6732
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10110001
CURRENT_STATUS
02
SITE_LOCATION
6732 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WATERLOO\6732\PR0231830\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
196
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page-6—of S <br /> 7. UNDER-DISPENSER CONTAINMENT TESTING <br /> Test Method Developed By: U UDC Manufacturer L]Qndustry Standard U Professional Engineer <br /> U Other(Specify) <br /> Test Method Used: U Pressure U Vacuum XJ Hydrostatic <br /> U Other(Specify) <br /> Test Equipment Used: Caldwell Equipment Resolution: <br /> UDC# tFb <br /> UDC# UDC# <br /> UDC Manufacturer. <br /> UDC Material: Fiberglass lass <br /> UDC Depth: " <br /> Height from UDC Bottom to Top Bottom Bottom <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to , <br /> Lowest Electrical Penetration: Bottom Bottom <br /> Condition of UDC prior to <br /> testing: Clean/Dry Clean/Dry <br /> Portion of UDC Tested' 811 811 <br /> Does turbine shut down when 4iyes UNo UNA <br /> UDC sensor detects either Xl Yes UNo UNA UYes UNo UNA UYes UNo UNA <br /> product orwaterT' Suction Pump Suction Pum <br /> Turbine shutdown responsetime 1 second 1 second <br /> Is system programmed for fail- O(Yes UNo UNA <br /> K1 <br /> safe shutdown?' Yea UNo UNA UYes 'UNo UNA UYes UNo UNA <br /> Was fail-safe verified to be 9Yes UNo UNA )QYes tiNo UNA UYes UNo UNA UYes UNo UNA <br /> operational?' <br /> Wait time between applying <br /> pressure/vacuum/water and hr. h r. <br /> starting test <br /> Test Start Time: 10 : 30 10: 30 <br /> Initial Reading 0 0 <br /> Test End Time: 11 &00 11 •00 <br /> Final Reading <br /> Test Duration: – hr. <br /> Chane in Reading .. 0 0 <br /> Pass/Fail Threshold orCriterla: 0 Loss 0 Loss <br /> Test Result: XI Pus U Fall 19 Pass U Fall U Pus U Fall U Pass U Fall <br /> Was sensor removed for testing? Q(Yes It No U NA XI Yes U No U NA U Yes U No U NA UYes UNo UNA <br /> Was sensor properly replaced and KYes UNo UNA YLI Yes UNo UNA UYes UNo UNA U Yes U No U NA <br /> verified functional after testing? <br /> CoMmenIs— (include informadon on repairs made prior to testing, and recommended follow-up forfailed tests) <br /> Diepenser pan sensor alarm turns off Suction Pump Motors. <br /> If the testing method does not test the entire depth of the UDC,specify how much of the UDC was tested. Methods not testing the <br /> entire UDC should only be used if the monitoring system provides fail-safe turbine shutdown. (See SWRCB LG-160) <br /> a With the submersible pump running,place the sensor in product(discriminating sensors should also be placed in water). The time <br /> between placing the sensor in product and the turbine shutting down is the response time. This should be done if the secondary <br /> containment testing method used does not test the entire volume of the UDC <br /> This information is not needed if the entire UDC is tested. <br />