My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2420
>
2300 - Underground Storage Tank Program
>
PR0231580
>
COMPLIANCE INFO 2012 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2021 2:41:11 PM
Creation date
12/21/2018 3:49:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2017
RECORD_ID
PR0231580
PE
2361
FACILITY_ID
FA0003963
FACILITY_NAME
TRACY76
STREET_NUMBER
2420
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
Tracy
Zip
95377
APN
23802006
CURRENT_STATUS
01
SITE_LOCATION
2420 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
280
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for TRACY76 as of August 09, 2017. <br /> Open violations from May 09, 2017 inspection <br /> Violation #204-Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. Immediately locate and retain a copy on site. <br /> Violation #206 - Failure to comply with UST operating permit conditions. <br /> A copy of the UST operating permit was not found on site. A copy of the UST operating permit and all attachments <br /> and conditions shall be retained at the facility. Immediately obtain a copy of the permit and retain it on site. <br /> Violation #313 - Failure to construct, operate, and maintain primary containment as product-tight. <br /> Oily debris was found underneath the sheer valve in the under dispenser containment for dispenser 1/2, indicating a <br /> leak in the primary piping. All primary containment for the UST system must be tight. Immediately have a properly <br /> licensed, trained, and certified contractor repair or replace the failed component under permit and inspection of the <br /> EHD. <br /> Open violations from May 03, 2016 inspection <br /> Violation #103 - Current financial responsibility documents not submitted. <br /> Financial responsibility documents have not been submitted to the EHD. Certification of Financial Responsibility <br /> and Letter from Chief Financial Officer documents found in the California Environmental Reporting System (CERS) <br /> are both dated May 20, 2014. Current financial responsibility documents are required to be submitted annually. <br /> Immediately log into CERS at http://cers.calepa.ca.gov/, and upload the required documents. <br /> Violation #105 - Current BOE number not submitted. <br /> UST Facility Operating Permit Application is lacking BOE Maintenance Fee Account Numbers or BOE number is <br /> incorrect. The BOE number 44813494 found in CERS is not a valid number. Immediately log into CERS, update the <br /> required information, and submit for review by the EHD. <br /> Violation #107 - Plot plan/site map not submitted or failed to completely show where monitoring is <br /> performed. <br /> An accurate UST Monitoring Site Plan was not submitted. A site plan must be submitted identifying the locations <br /> where monitoring will be performed. Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> Violation #113- Failed to submit monitoring system certification test report within 30 days. <br /> A monitoring system certification, leak detector testing, and spill container testing were performed on May 18, 2015. <br /> A test report has not been submitted to the EHD or the California Environmental Reporting System (CERS). A copy <br /> of the test report must be submitted within 30 days of the test. Immediately provide this report to the EHD. <br /> Violation #121 - Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on May 18, 2015 and an inspection report was issued identifying information to be <br /> submitted to bring this site into compliance. This information was required to be submitted by June 17, 2015. This <br /> information has not been received resulting in a non-compliant status for this facility. An operator that receives an <br /> inspection report shall have 30 days to submit a written response that includes a statement documenting corrective <br /> actions taken or proposing corrective actions which will be taken. Ensure that a written response documenting <br /> corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. Be sure to <br /> include secondary containment test results for May 14, 2012, May 18, 2015, and June 15,2015 to the EHD. <br /> Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.