My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0003988
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LODI
>
851
>
3500 - Local Oversight Program
>
PR0544084
>
ARCHIVED REPORTS XR0003988
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2019 3:07:44 AM
Creation date
1/31/2019 4:33:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0003988
RECORD_ID
PR0544084
PE
3500
FACILITY_ID
FA0005447
FACILITY_NAME
LODI READY MIX & BLDG MATERIAL
STREET_NUMBER
851
Direction
E
STREET_NAME
LODI
STREET_TYPE
AVE
City
LODI
Zip
95240
CURRENT_STATUS
02
SITE_LOCATION
851 E LODI AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Lodi Ready Mix Page 2 <br /> Site Closure Report <br /> Appendix D <br /> May 12,1995 <br />' Sampling and Analyses <br /> 1) Additional soil samples were collected from areas suspected to contain <br />' PHC. <br /> 2) Sampling and analyses protocol appeared to conform to standards <br />' prescribed by LUFT and the TRBSR at time of performance. <br /> 3) Appropriate soil sample analyses were used as per Table 2. <br /> 4) QA/QC results were submitted. <br />' 5) The site does not exhibit a high water table (not in contact with excavation) <br /> as evidenced by drilling to 42 feet below surface grade without encountering <br /> ' groundwater. Groundwater surface maps show that the depth to <br /> groundwater is approximately 53 feet below ground surface and that in "wet" <br /> years may be as high as 40 feet below ground surface <br /> ' 6) Soil samples were collected from the piping runs. <br /> 7) Depth and location of soil samples were submitted. <br /> CRWQCB Closure Checklist as per March 1, 1994 Tri-Regional Board Staff <br /> ' Recommendations for Preliminary Evaluation and Investigation of <br /> Underground Tank Site, Appendix B, Central Valley Regional Water Quality <br /> Control Board Staff Recommendations for Closure Requests <br /> ' 1) The distance to nearest wells within 2,000 ft was not evaluated. <br /> ' 2) Site Maps are attached <br /> 3) Tabulated results of soil data presented in section S of this report <br /> 4) Hi ort and low water levels discussed in Section 3 of this re h g p <br /> ' 5) Vertical and lateral concentration contours of remaining PHC <br /> 6) A very conservative mass balance shows that approximately 3.6 gallons of <br /> diesel may remain after excavation. <br /> ' 7) Remedial action was performed by excavation. <br />