Laserfiche WebLink
SWRCB, January 2002 <br />S. FILL RISER CONTAINMENT SUMP TESTING <br />Page 10 of <br />Facility is Not Equipped With Fill Riser Containment Sums ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer DIndustry Standard []Professional Engineer <br />[]Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum OHydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: TS -STS <br />Equipment Resolution: 0.00" <br />Sump Diameter: <br />Fill Sump # 91 <br />Fill Sump # 87-1 <br />Fill Sump # 87-2 <br />Fill Sump # 87 Slave <br />39.00" <br />39.00" <br />39.00" <br />39.00" <br />Sump Depth: <br />72.00" <br />72.00" <br />72.00" <br />72.00" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />18.00" <br />18.00" <br />18.00" <br />18.00" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />40.00" <br />40.00" <br />40.00" <br />40.00" <br />Condition of sump prior to <br />testing: <br />Clean dry <br />Clean dry <br />Clean dry <br />Clean dry <br />Portion of Sump Tested <br />Highest penetration <br />Highest penetration <br />Highest penetration <br />Highest penetration <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />5min <br />5min <br />5min <br />5min <br />Test Start Time: <br />Initial Reading (RI): <br />SEE INCON RESULTS <br />SEE INCON RESULTS <br />SEE INCON RESULTS <br />SEE INCON RESULTS <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />15min <br />15min <br />15min <br />15min <br />Change in Reading (RF-Rj): <br />Pass/Fail Threshold or Criteria: <br />0.002" <br />0.002" <br />0.002" <br />0.002" <br />Test Result: <br />" Pass ❑ Fail <br />" Pass ❑ Fail <br />" Pass ❑ Fail <br />" Pass ❑ Fail <br />Is there a sensor in the sump? <br />O Yes []No <br />O Yes ❑ No <br />O Yes ❑ No <br />"Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />❑ Yes ❑No ONA <br />❑Yes ❑No ONA <br />❑Yes ❑No ONA <br />❑Yes ❑No ONA <br />Was sensor removed for testing? <br />O Yes ❑No ONA <br />OYes No ❑NA"Yes <br />❑No [INAOYes <br />❑No ONA <br />Was sensor properly replaced and <br />verified functional after testing? <br />O Yes ❑ No [INA <br />OYes []No ONA <br />"Yes []No ONA <br />OYes ❑No ONA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />