My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2009 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:35:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2012
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
379
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DEC-05-2011 10:31 SERVICE STATION 14089388888 P.08i10 <br /> r. <br /> Y.. <br /> 8, UNDER-DISPENSER CONTAINMENT UDC TESTING <br /> Test Method Developed By: ❑ UDC Manufacturer ® Industry Standard q Professional Engineer ^ ` <br /> ❑ Other(Spec) <br /> Test Method Used; ❑Prossure rj Vacuum M Hydrostatic <br /> t- <br /> ❑ Other(Spec) <br /> A. <br /> Test Equipment Used: Incon Sump Tester Equipment Resolution: +/-0.002" <br /> SEMMES= men= <br /> UDC#9/10 UDC#11/12 UDC# 13/14 UAC# 15/161; <br /> CJDC Manufacturer: Western fiberglass Western fibergla_cs Western fiberglass Western fiberglass <br /> UDC Material; Fiberglass Fiberglass Fiberglass Fibertrlass <br /> UDC Depth: 31" 31" 31++ 31" <br /> Height from UDC Bottom to Top 5" 5" 5" 5" - <br /> of Highest Piping Penetration: _ ` <br /> Height from UDC Bottom to 12" ]0" 10" I O" <br /> Lowest Electrical Penetration:. <br /> Condition of UDC prior to <br /> testin Good Good Good Good <br /> Portion of UDC Tested 2"above i in 2"above piping 2"above pipin2" above pipin <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes ❑No M NA ❑Yes ❑No ®NA ❑Yes❑No (SNA ❑Yes❑No ®NA- <br /> roduct and water)?' <br /> Turbine shutdown response time N/A N/A N/A N/A <br /> Is system programmed for fail- <br /> safe shutdown? ❑Yes ❑No f3 NA I_]Yes ElNo ®NA ❑ Yes ElNo ®NA ElYes ElNo <br /> ®NA- <br /> Was fail-safe verified to be <br /> ❑Yes ❑No ®NA ❑ Yes[]No ❑NA ❑Yes ❑No ®NA ❑ Yes❑No ®NA <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test <br /> Test Start Time: 1:16 pm 1:16 pTn 1:16 pm 1:16 pm <br /> Initial Readin R,): 4.1304 2.8120 1.7103 5,527I ,u <br /> Test End Time: 1:31 pm 1:31 Pm 1:31 em 131 pm ;s <br /> Final Readin (Rr). 4.1307 2.8123 1,7109 5.5276 Y <br /> Test Duration: 15 min. 15 min, 15 min. 15 min. <br /> Chane in Reading(RF-R,): +0.0003 +0.0003 +0.0006 +0.0005 <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002" +/-0.002" +/-0.002" <br /> Test Result: ® Pass ❑Fail ® Pass 0 Fail 191 Pass 11 Fa0 M Pass ❑Fail <br /> Was sensor removed for testing? ®Yes❑No ❑NA ®Yes❑No ❑NA ®Yes❑No lD NA ®Yes ❑No ❑NA' , <br /> Was sensor properly replaced and <br /> verified functional after testing? O Yes❑No❑NA 0 Yes❑No ❑NA M Yes❑No ❑NA ®Yes ❑No ❑NA <br /> Cominents—(include information on repairs made prior to resting, and recommended follow-up for failed tests) <br /> "Sensor functionality was not confirmed. This procedure 1s not part of the Secondary Containment testing scope of work", <br /> '.J <br /> Si <br /> .L <br /> :yyi.,,. •a <br /> t, <br /> If the entire.depth of the UDC is not tested, specify how much was tested. if the answer to ani of the questions indicated with an <br /> asterisk(*) is "NO" or"NA", the entire UDC must be tested_ (See SWRCB LG-160) <br /> .r' <br />
The URL can be used to link to this page
Your browser does not support the video tag.