My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0001036
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1245
>
3500 - Local Oversight Program
>
PR0544236
>
ARCHIVED REPORTS XR0001036
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2019 6:12:20 PM
Creation date
3/6/2019 4:14:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0001036
RECORD_ID
PR0544236
PE
3526
FACILITY_ID
FA0024238
FACILITY_NAME
JM EQUIPMENT COMPANY
STREET_NUMBER
1245
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323034
CURRENT_STATUS
02
SITE_LOCATION
1245 W CHARTER WAY
P_LOCATION
01
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Ceofa$ua(Teahnws Inc 0 0 Page 4 <br /> Monitoring Well Installation Work Plan <br /> J M Equipment Co <br />' Project No 507 2 <br /> January 17, 1997 <br />' Before sampling is attempted the well will be sounded for depth to water and then a clear <br /> disposable bailer will be used to determine if floating product is present The well will be <br /> purged of at least 3 well volumes of stagnant water using either a submersible pump or a <br />' stainless steel bailer Purging will continue until the temperature, conductivity, and pH of the <br /> ground water has stabilized (<10% variation between three readings) indicating that <br /> formation water representative of aquifer conditions is entering the well These water quality <br /> parameters are measured at intervals of each well volume purged In addition, the parameters <br />' of dissolved oxygen (D O ) and oxidation-reduction potential (O R P ) will be measured and <br /> recorded <br />' A stainless steel or disposable plastic bailer will be used to collect each sample Care will be <br /> taken to minimize sample agitation from the initial filling of the bailer to the transfer of the <br /> sample to the VOA vial and glass amber Iiter bottles Once the sample container is filled and <br />' capped, the bottle will be inverted, tapped, and checked for head space bubbles The sample <br /> container is identified and labeled with a unique designation, inserted into foam holders and <br /> placed in an ice chest cooled to 4°C for transport to the laboratory <br />' All non disposable sampling equipment is decontaminated using a steam cleaner before and <br /> between uses The effectiveness of the decontamination procedure is ensured by using the <br /> following quality control measures <br />' • Disposable gloves will be used by the technician to collect all samples and will be <br /> changed with each sampling event <br /> G A bailer blank for each well will be collected prior to sampling by filling the <br /> decontaminated stainless steel bailer with water (provided by the laboratory) and then <br /> filling a VOA vial (provided by the laboratory) using the same procedures for actual <br /> sample collection <br /> Bailer blanks for each sample, along with a field blank (prepared from water provided by the <br /> laboratory poured into a VOA vial on site), will accompany the samples to the laboratory and <br /> serve as checks against cross contamination <br /> A chain of custody document, listing all samples collected, accompanies the samples from <br />' field to laboratory, thereby providing a means to track their movement and insure their <br /> integrity <br />' All water purged from each monitoring well and not used as a sample, will be placed in a 55 <br /> gallon DOT approved container, properly labeled and stored on site <br />' 2.2.1 Ground water Sample Analyses <br /> One ground water sample from each well will be submitted to Sherwood Laboratories of <br /> Hilmar (State Certified Laboratory 41400) and analyzed for benzene, toluene, ethylbenzene <br /> and xylene (BTEX) by EPA method 8020. Gasoline range petroleum hydrocarbons (TPH- <br /> Gas) by EPA method 8015(m), Methyl Tertiary Butyl Ether (MTBE) by EPA method 8020 <br />' with confirmation by 8260 and diesel range petroleum hydrocarbons analyses (TEPH-Diesel <br /> by EPA method 3540/8015m) The detection limits for these compounds are listed below A <br /> Chain of Custody will be completed for all samples collected and tracked to ensure sample <br /> integrity <br />
The URL can be used to link to this page
Your browser does not support the video tag.