My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001 - 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
6100
>
2300 - Underground Storage Tank Program
>
PR0231630
>
COMPLIANCE INFO_2001 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
3/21/2019 1:31:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2016
RECORD_ID
PR0231630
PE
2361
FACILITY_ID
FA0003630
FACILITY_NAME
ARCO STATION #595*
STREET_NUMBER
6100
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08704034
CURRENT_STATUS
02
SITE_LOCATION
6100 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
249
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer N Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑ Pressure ❑ Vacuum N Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Wayne Perry Inc. Equipment Resolution: _0007" <br /> Sump# — Sump# V21-1 Sump# Sump# <br /> Sump Diameter: 2' " <br /> Sump Depth: <br /> Sump Material: <br /> Height from Tank Top to Top of „ <br /> Highest Piping Penetration: 1-7 `Z <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: 12, <br /> Condition of sump prior to testing: t OKAY OKAV <br /> Portion of Sump Tested' 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST <br /> PIPING PENETRATION PIPING PENETRATION PIPING PENETRATION PIPING PENETRATION <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes ❑No N NA ❑Yes ❑No NNA ❑Yes ❑No NNA ❑Yes ❑No N NA <br /> product and water)?* <br /> Turbine shutdown response time NA NA NA <br /> Is system programmed for fail-safe ❑Yes ❑No N NA ❑Yes ❑No N NA ❑Yes ❑No N NA ❑Yes ❑No N NA <br /> shutdown?* <br /> Was fail-safe verified to be <br /> orational?* [IYes []No N NA [IYes []No N NA ❑Yes ❑No N NA ❑Yes ❑No N NA <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> test: <br /> Test Start Time: y <br /> Initial Reading(RD: 1z) <br /> Test End Time: �' <br /> Final Reading(RF): zo <br /> Test Duration: 115m 15 Min 15 Min 15 Min IS Min 15 Min 15 Min IS Min <br /> Change in Reading(RF-Rt): .t �j mo l3Pass/Fail Threshold or Criteria: 0 -0.00 -0.002 -0.0020 -0. -0.0020 -0.0020 -0.0020 <br /> j _ <br /> Was sensor removed for testing? Yes ❑No ❑NA EXYes ❑No ❑NA 'ZYes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and <br /> verified functional after testin ? E&Yes El No El NA ( .Yes ElNo El NA .Yes El No El NA El Yes El No El NA <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br />