My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2300 - Underground Storage Tank Program
>
PR0231706
>
COMPLIANCE INFO_2014 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2019 2:30:29 PM
Creation date
4/10/2019 4:46:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014 - 2018
RECORD_ID
PR0231706
PE
2361
FACILITY_ID
FA0000485
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
05532024
CURRENT_STATUS
01
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
374
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.oM/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />FLAG CITY CHEVRON <br />6421 CAPITOL AVE, LODI <br />September 26, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />209 <br />CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to fill out the June 2017 designated operator inspection report completely. The <br />designated operator failed to check a box under "Has each alarm for the previous month been responded to <br />appropriately." During the monthly inspection, the designated operator shall review the alarm history for the previous <br />month, check that each alarm was documented and responded to appropriately, and attach a copy of the alarm <br />history with documentation taken in response to any alarms to the monthly report. Ensure that designated operators <br />performing monthly inspections at this facility are including all of the required information on the reports. <br />This is a repeat violation, Class ll. <br />210 <br />CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months. <br />The October 2016 through May 2017 designated operator monthly inspection reports were not found on site. <br />Designated operator monthly inspection reports for the previous twelve months shall be retained on site. Locate <br />and ensure that copies of the previous twelve months of designated operator monthly inspection reports are <br />maintained on site. Submit copies to the EHD. <br />This is a Class II violation. <br />211 <br />CCR 2715(f) Designated operator employee training not performed or log not kept. <br />The designated operator employee training records were not found on site. The designated operator shall train <br />facility employees for which he or she is responsible in the proper operation and maintenance of the UST system <br />once every 12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br />the training records to the EHD. <br />This is a Class II violation. <br />306 <br />CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br />In the 87 -octane (master) submersible turbine pump sump, the drain plug was left in place at the test boot. As such, <br />any potential release from the primary containment into the secondary containment in the 87 -octane (master) piping <br />does not flow into a collection sump. All secondary containment systems shall be sloped so that all releases will <br />flow to a collection sump located at the low point of the underground piping. Immediately contact a properly <br />licensed, trained, and certified contractor to ensure that any releases in the 87 -octane piping flows into the sump <br />with a sensor. Submit proof of correction to the EHD. <br />This is a Class II violation. <br />EHD 23-01 Rev. 09/22/16 <br />Page 6 of 7 <br />FA0000485 PR0231706 SCO01 09/26/2017 <br />Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.