S. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />_ ❑ Other (Spec) <br />Test Equipment Used: Incon Sump Tester Equipment Resolution: +/- 0.002" <br />Qy <br />Fill Sump # 87 <br />Fill Sump # 91 <br />Fill Sump # Diesel <br />Sump Diameter: <br />42" <br />42" <br />42" <br />Sump Depth: <br />68" <br />66" <br />68" <br />1 ieight from Tank Top to Top of <br />Highest Piping Penetration: _ <br />NIA <br />N/A <br />N/A <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />20" <br />20" <br />18" <br />Condition of sump prior to <br />testing: <br />Good <br />Good <br />Good <br />Portion of Sump Tested <br />2" above piping <br />2" above piping <br />2" above piping <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />12:07 pm <br />12:07 pm <br />12:07 pm <br />Initial Reading (R,): <br />4.0993 <br />6.4601 <br />6.3006 <br />Test End Time: <br />12:22 pm <br />12:22 pin <br />12:22 pm <br />Final Reading (RF): <br />4.0984 <br />6.4593 <br />6.3005 <br />Test Duration: <br />15 min. <br />15 min. <br />15 min. <br />Chane in Reading (RI: -RI): <br />0.0009 <br />0.0008 <br />0.0001 <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />Test Result: <br />© Pass 0 Fail <br />El Pass 0 Fail <br />OO Pass 0 Fail <br />Is there a sensor in the sump? <br />® Yes ❑ No <br />® Yes ❑ No <br />® Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />❑ Yes ❑ No ® NA <br />❑ Yes [I No ® NA <br />❑ Yes ❑ No ® NA <br />Was sensor removed for testing? <br />® Yes [j No C] NA <br />®Yes ❑ No ❑ NA <br />®Yes C] No C] NA <br />Was sensor properly replaced and <br />verified functional after testing, <br />®yes ❑ No El NA <br />®Yes ❑ No [INA <br />®Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work <br />