My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 1:14:28 PM
Creation date
4/29/2019 2:10:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />_ ❑ Other (Spec) <br />Test Equipment Used: Incon Sump Tester Equipment Resolution: +/- 0.002" <br />Qy <br />Fill Sump # 87 <br />Fill Sump # 91 <br />Fill Sump # Diesel <br />Sump Diameter: <br />42" <br />42" <br />42" <br />Sump Depth: <br />68" <br />66" <br />68" <br />1 ieight from Tank Top to Top of <br />Highest Piping Penetration: _ <br />NIA <br />N/A <br />N/A <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />20" <br />20" <br />18" <br />Condition of sump prior to <br />testing: <br />Good <br />Good <br />Good <br />Portion of Sump Tested <br />2" above piping <br />2" above piping <br />2" above piping <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />12:07 pm <br />12:07 pm <br />12:07 pm <br />Initial Reading (R,): <br />4.0993 <br />6.4601 <br />6.3006 <br />Test End Time: <br />12:22 pm <br />12:22 pin <br />12:22 pm <br />Final Reading (RF): <br />4.0984 <br />6.4593 <br />6.3005 <br />Test Duration: <br />15 min. <br />15 min. <br />15 min. <br />Chane in Reading (RI: -RI): <br />0.0009 <br />0.0008 <br />0.0001 <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" <br />+/- 0.002" <br />+/- 0.002" <br />Test Result: <br />© Pass 0 Fail <br />El Pass 0 Fail <br />OO Pass 0 Fail <br />Is there a sensor in the sump? <br />® Yes ❑ No <br />® Yes ❑ No <br />® Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />❑ Yes ❑ No ® NA <br />❑ Yes [I No ® NA <br />❑ Yes ❑ No ® NA <br />Was sensor removed for testing? <br />® Yes [j No C] NA <br />®Yes ❑ No ❑ NA <br />®Yes C] No C] NA <br />Was sensor properly replaced and <br />verified functional after testing, <br />®yes ❑ No El NA <br />®Yes ❑ No [INA <br />®Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work <br />
The URL can be used to link to this page
Your browser does not support the video tag.