My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 1:14:28 PM
Creation date
4/29/2019 2:10:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IMPORTANT: The instructions below for the 7150 <br />Overfill Prevention Valve are written for the initial <br />stage shutoff at 95%, but can be adjusted to shutoff <br />at any desired tank capacity. Please contact the Au- <br />thority Having Jurisdiction (AHJ) and review local, <br />state, and national codes to determine the regulato- <br />ry requirements governing shut-off capacity in your <br />region, as well as take into account other considera- <br />tions such as extreme tank tilt. In all cases, the up- <br />per tube must protrude into the tank at least 61 /2" <br />to ensure that the valve can shut off flow into the <br />tank completely before the top of the tank is wetted <br />as per EPA requirements. <br />HOW TO LOCATE THE POSITION OF THE 71 SO AT <br />95% TANK CAPACITY <br />(Shut-off points can be adjusted to any capacity to <br />comply with AHJ Requirements) <br />The length of the upper tube and the placement of the <br />71 SO valve body determine the shut-off point. Follow- <br />ing the standard instructions for the OPW 71 SO will pro- <br />vide for initial shutoff at 95%. In all cases, the upper <br />tube length must be a minimum of 6-1/2" plus the <br />length of the riser pipe. All length measurements are in <br />inches. <br />INSTRUCTIONS <br />1) Find tank capacity (in gallons) from tank calibration <br />chart provided by tank manufacturer. <br />2) Calculate 95% of capacity <br />3) Locate the 95% volume <br />number on the tank calibra- <br />tion chart. <br />4) Find the dipstick number (X) which corresponds to <br />the 95% tank volume. And, find the dipstick num- <br />ber (Y) which corresponds to the 100% volume. <br />5) Subtract the dipstick number (X) from the tank di- <br />ameter (Y) to find the upper tube reference number <br />(Z). <br />6) Subtract 2"from (Z) to find the upper tube depth <br />7) Is C less than 6-1/2"? <br />NO Upper tube length is C plus the distance from <br />the top of the Face Seal Adaptor installed on <br />the riser pipe to the inside, top lip of the storage <br />tank (A). <br />Upper Tube Length = C + (A) <br />For testable models only, ending in "T": <br />Upper Tube Length = C + (A) — 1-1 /2" <br />YES Upper tube length is 6-1 /2" plus the riser pipe <br />measurement (A). <br />Upper Tube Length = 6-1 /2" + (A) <br />For testable models only, ending in "T": <br />Upper Tube Length = 6-1 /2" + (A) - 1-1 /2" <br />NOTE: You must find the actual tank capacity num- <br />ber that correlates to the 6-1 /2" + (A) depth for the <br />station records. This number may also be used for <br />the purposes of calibrating an electronic tank level <br />system. <br />Tape measure <br />Riser Pipe <br />with Face (A) <br />Seal Adaptor To Tank <br />(B) <br />Top (I.D) <br />To Tank <br />Bottom <br />L r <br />Figure 1 <br />EXAMPLE <br />1) Foran Owens-Corning Model G-3 Fiberglass®Tank <br />Calibration Chart: <br />Tank Capacity - 10,000 gal., nominal 9,403 gal. <br />NOTE: Use actual capacity only <br />2) 95% of actual tank capacity = 0.95 x 9403 gal. _ <br />8933 gal. <br />3) The closest number which is less than 8933 gal. Is <br />8910 gal. Choosing the closest number less than <br />95% of actual capacity ensures that the initial <br />shutoff will occur when the tank is no more than <br />95% full. <br />4) The calibration chart reading of 8910 gal, corre- <br />sponds to a dipstick measurement of 82". <br />
The URL can be used to link to this page
Your browser does not support the video tag.