Personal Protective Equipment <br /> Hard Hat <br /> Gloves <br /> Long Pants <br /> Long Sleeved Shirt <br /> Protective Goggles/Glasses <br /> Note: During the process of air monitoring, should the levels rise to or exceed 300 ppm, <br /> under the direction and discretion of the Project Manager, and/or the Project Site Safety <br /> Officer, all personnel will be required to enter into level 'C' protection. <br /> Air Monitoring Safety <br /> An H Nu properly calibrated shall be available if the Project Manager deems it necessary, <br /> and monitored by the Project manager. A Gas Tech currently calibrated monitor shall be <br /> displayed to the Fire Marshal representative present for approval prior to usage and said <br /> official shall be afforded full and complete inspection/monitoring or usage at the time of <br /> the product line removal. <br /> The work shall only take place during the light of day and not take place in darkness at <br /> any time. <br /> Decontamination Procedures <br /> Any person coming in contact with the petrohydrocarbon chemical(s) shall receive <br /> immediate and extensive cleaning in a rinse of clean water. <br /> Saline solution shall be immediately and extensively applied to eyes exposed.Skin shall be <br /> immediately treated with the appropriate ointment and wrapped with sterile gauze. <br /> The immediate decontamination to be used to decontaminate clothing or equipment shall <br /> be; TriSodium Phosphate and any decontamination fluids expended in the process shall be <br /> collected and properly disposed of and not allowed to enter the ecological system when at <br /> all possible. <br /> 6 <br />