My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO 2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2019 5:10:41 PM
Creation date
5/15/2019 2:24:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
518
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sioov.ora/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility <br />Name. Safeway Fuel #2707 <br />Facy <br />Add ess. 6425 Pacific Ave., Stockton <br />Inspection <br />Date: Jan 21, 2014 <br />VIOLATIONS <br /># <br />Ct <br />C2 <br />M <br />Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />On Site Records (continued) <br />204 <br />CCR 2715(c) <br />Designated operator monthly inspection: (1) alarms not documented; (24) spill containers, Wes, and sumps <br />if necessary) not ins ected; 5 required test dates not checked or noted; 6 employee training not verified <br />205 <br />CCR 2715(e) <br />Designated operator monthly inspection reports not maintained on site for at least 12 months <br />206 <br />CCR 2715(f) <br />Designated operator employee training: (1) not performed; (2) not current for at least one employee on site; <br />3 log not kept <br />207 <br />HSC 25281.5(b)(2) <br />Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br />Observations <br />301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br />302 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary containment(Mt) <br />303 X CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (M7) <br />304 CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST (M1) <br />305 X CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping & UDcs that activates an (111) <br />audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br />306 CCR 2631(a) Primary containment is not product tight <br />307 X NSC 25291(a)(2) Secondary containment for UST system is not tight <br />308 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br />309 CCR 2636(a) Failed to have secondary containment for piping (includes conventional suction piping) (M2) <br />310 HSC 25291(e) Water in 2° containment not removed, analyzed & property disposed of <br />311 CCR 2636(f)(2) Line leak detector(s) not installed or failed to detect a 3 -gallon per hour leak at 10 psi (M1) <br />312 CCR 2635(b) No spill container or overfill prevention system installed (M2) <br />313 X CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons, or failed to provide a means to keep (M2) <br />the spill container empty <br />314 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements (M2) <br />315 HSC 25299(f)(2) Tampering with or disabling leak detection devices or alarms <br />316 CCR 2631.1(a) UST system is not compatible with the substance stored <br />317 HSC 25298(a) Illegally abandoned UST system <br />AS 1702 (2003-2004) HSC 25290.2 (installed between 07101103 and 06130104) <br />VPH Systems HSC 25290.1 Installed on or after 07101104 <br />401 <br />CCR 2631.1 <br />Compatibility and permeability requirements: (a) UST system is not compatible with the substance stored; (b) <br />results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b) and (d) <br />for a UST system installed after July 1, 2004, were not submitted <br />402 <br />X <br />HSC 25290.1(c)(1) <br />HSC 25290.2(c)(1) <br />Primary containment not liquid or vapor tight <br />403 <br />HSC 25290.1(c)(2) <br />HSC 25290.2(c)(2) <br />Secondary containment not liquid or vapor tight <br />404 <br />X <br />HSC 25290.1(c)(3) <br />HSC 25290.2(c)(3) <br />Secondary containment not constructed to prevent water intrusion <br />405 <br />HSC 25290.1(d) <br />HSC 252902(d) <br />Monitoring system not maintained to detect water intrusion into the secondary containment, or the entry of <br />liquid or vapor from the primary containment into the secondary containment <br />406 <br />HSC 25290.1(e) <br />Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial space of the <br />UST system not maintained <br />407 <br />HSC 25290.10) <br />HSC 25290.2(i) <br />UST system not tested by one of the following methods prior to use: (1) Enhanced leak detection; (2) inert gas <br />pressure test approved b SWRCS; 3 test method deemed a uivalent to 1 or 2 b the SWRCB <br />Emergency Generator Systems <br />501 <br />CCR 2636(f)(6) <br />Emergency generator monitoring system not checked daily or log not kept if no leak detector IMI) <br />502 <br />HSC 25281.5(b)(3) <br />Unburied fuel piping not visually inspected at least monthly or log not kept (M1) <br />USTs In a Vault <br />601 HSC 25283.5(a)(1) All exterior surfaces of the tank and connected piping cannot be directly viewed <br />602 HSC 25283.5(a)(2) Structure that the UST is located in does not provide for secondary containment <br />603 HSC 25283.5(a)(3) Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br />604 HSC 25283.5(a)(5) UST installed after July 1, 2003, does not meet or exceed applicable sections of HSC 25291 <br />Non -Pressurized Piping <br />701 CCR 2643(d) Daily monitoring of suction piping (pre -January 1, 1984) not performed (Mt) <br />leweaor <br />Stacy Rivera (209) 468-3440 <br />ar <br />nee: <br />EHD23-02 Rev04/22A3 v v Paget UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.