My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO 2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2019 5:10:41 PM
Creation date
5/15/2019 2:24:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
518
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.oro/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Safeway Fuel #2707 <br />Name: y <br />Fad'4 6425 Pacific Ave., Stockton <br />Address: <br />Inspection Jan 21, 2014 <br />Date. <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Coda Section <br />HSC = CA Health and 5 Code; CFR = Code or Federal Regulafians <br />C1 = Class 1 violation, C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (Mi) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre-January1, 1984) (M1) <br />Other Violations <br />999 1 10ther: See attached "Continuation — Official Inspection Report' for mlation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />ROUTINE ANNUAL INSPECTION AND MONITORING SYSTEM CERTIFICATION <br />Class II violations: (303, 305, 307, 402) <br />303. The 87 fill sump sensor was lying on its side and not located to detect a leak at the earliest <br />opportunity. Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible <br />opportunity. The sensor was relocated into proper positioning at the time of inspection. <br />305. The diesel fill sump sensor failed to activate an audible and visual alarm when tested to ensure <br />continuous monitoring of the tank system. All monitoring equipment shall be maintained to activate an <br />audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. The sensor <br />was replaced and retested during the inspection. A "UST Retrofit Verification with Inspector Already <br />Onsite" form has been completed and provided to the operator and contractor. <br />307. The January 8, 2013 secondary containment test results indicate a failure at the vent sump. A <br />permit application was submitted to the EHD, but was incomplete and has not been approved. All <br />secondary containment for the UST system must be tight. Immediately have a properly licensed, <br />trained, and certified contractor repair or replace the failed component under permit and inspection of <br />the EHD. <br />402. A fuel leak was found at dispensers 1/2, 3/4, and 7/8; dripping was observed under these <br />dispensers. All primary containment must be impervious to the liquid and vapor of the substance <br />contained. Immediately discontinue use of failed piping and have a properly licensed, trained, and <br />certified contractor replace or repair the failed piping under permit and inspection of the EHD. If the <br />failed component can't be replaced immediately, there is a possibility that the UST system may be red <br />tagged to prevent fuel inputs. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION T ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Inspector: <br />Title: <br />EHD 23-02 R.Td/19/12 v Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.