My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
900
>
2300 - Underground Storage Tank Program
>
PR0231841
>
COMPLIANCE INFO 2011 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 1:58:23 PM
Creation date
7/12/2019 1:58:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2017
RECORD_ID
PR0231841
PE
2361
FACILITY_ID
FA0000556
FACILITY_NAME
CHEROKEE LANE SERVICE STATION*
STREET_NUMBER
900
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04742007
CURRENT_STATUS
01
SITE_LOCATION
900 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />CONTINUATION FORM <br />Page: 4 of <br />OFFICIAL INSPECTION REPORT <br />Date: 02/07/14 <br />Facility Address: 900 S Cherokee Lane, Lodi, CA <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS 11, or MINOR -Notice to Comply) <br />110. Annual diesel leak detector testing and positive shut down verification for diesel turbine was last <br />performed on October 29, 2012 and was due by October 29, 2013. These tests are required once every <br />12 months. These tests were conducted on February 7, 2014 and were over three months past due. <br />Take all necessary precautions to ensure that all future testing is performed in a timely manner. Please <br />be aware that this follow-up inspection, to verify diesel leak detector functionality and observe <br />positive shut down and fail safe, is being charged at our current hourly rate. <br />106 & 202. Current approved copies of the monitoring and response plans were not found on site. The <br />monitoring and response plans must be current and approved by the EHD. Immediately log into CERS, <br />update the monitoring plan information, and submit for review by the EHD. Complete a monitoring plan <br />record for each tank. Immediately submit a copy of the response plan to the EHD for approval. <br />Alternatively, log into CERS, upload the completed form, and submit for review by the EHD. Maintain an <br />approved copy on site. <br />201. The 2010 and 2012 annual monitoring system certification and 2012 secondary containment test <br />results were not found on site. These records shall be kept on site for at least 3 years. Immediately <br />locate and maintain these documents onsite and submit copies to the EHD. <br />206. The designated operator employee training for all employees was not performed. The designated <br />operator shall train facility employees for which he or she is responsible in the proper operation and <br />maintenance of the UST system once every 12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator and maintain the list on site. A <br />copy of the designated operator employee training record for training conducted on October 29, <br />2013 was received on February 7, 2014. <br />Notes: <br />1. A line test was performed on October 29, 2013 by David Winkler on the Diesel line since the diesel <br />tank top turbine could not be started and positive shut down could not be verified. David Winkler's <br />certifications: Petrotite Line Tester: 5-8-2015, Tank Tested: 3-31-2014. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Received <br />Title: <br />Elena Manzo (209) 953-7699 <br />EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.