My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EMBARCADERO
>
6649
>
2300 - Underground Storage Tank Program
>
PR0231098
>
COMPLIANCE INFO 2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2020 4:45:55 PM
Creation date
7/24/2019 9:18:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231098
PE
2361
FACILITY_ID
FA0003830
FACILITY_NAME
VILLAGE WEST MARINA
STREET_NUMBER
6649
STREET_NAME
EMBARCADERO
STREET_TYPE
DR
City
STOCKTON
Zip
95219
APN
09815006
CURRENT_STATUS
01
SITE_LOCATION
6649 EMBARCADERO DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
388
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB January 2002 <br />c 1 �.: , <br />"EIV <br />Page _ of _ <br />6. PIPING SUMP TESTING APR 0 9 2015 � <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard <br />"al Engineer <br />MROWNtA® Other (Spec) Caldwell Sump Tester <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Caldwell Sump Tester Equipment Resolution: 0.005 Inches in <br />Sump Diameter: <br />Sump Depth: <br />Sump Material: <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Portion of Sump Tested' <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)? <br />Turbine shutdown response time <br />Is system programmed for fail-safe <br />shutdown?* <br />Was fail-safe verified to be <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />Test Start Time: <br />Initial Reading (Ri): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (ROQ: <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />Was sensor removed for testing? <br />Was sensor properly replaced and <br />verified functional after testin ? <br />Sump # 91 <br />44 inches <br />30 inches <br />Fiberglass <br />12 inches <br />10 inches <br />Dry <br />14 inches <br />N Yes l No DNA <br />5 sec <br />® Yes ❑No DNA <br />®Yes D No ❑ NA <br />15 min <br />10:15 <br />1" Ring <br />10:45 <br />1" Ring <br />30 min. <br />0 change <br />0.005 inches in '/2 <br />hour <br />® Pass ❑ Fail <br />®Yes ❑ No ❑ NA <br />Sump # Red Diesel <br />44 inches <br />30 inches <br />Fiberglass <br />12 inches <br />10 inches <br />Dry <br />14 inches <br />®Yes ❑No [INA <br />5 sec <br />®Yes DNo DNA <br />®Yes D No ❑ NA <br />15 min. <br />10:25 <br />1" Ring <br />10:55 <br />V Ring <br />30 min. <br />0change <br />0.005 inches in 1/2 <br />hour <br />® Pass ❑ Fail <br />g Yes ❑ No DNA <br />Sump # 1 <br />Transition <br />44 inches <br />54 inches <br />46 inches <br />40 inches <br />Dry <br />48 inches <br />Manual Valve Sump <br />#2 transition <br />36 <br />36 <br />Fiberglass <br />12 inches <br />10 inches <br />Dry <br />18 inches <br />®Yes ONO DNA I ®Yes ❑No DNA <br />5 sec <br />5 sec <br />®Yes ❑ No ❑ NA I ® Yes ❑ No [INA <br />g yes D No DNA I ®yes ❑ No [INA <br />15 min. <br />12:00 <br />1' Ring <br />12:30 <br />18'Ring <br />30 min. <br />0 change <br />0.005 inches in '/2 <br />hour <br />® Pass ❑ Fail <br />® Yes ❑ No ❑ NA <br />5 min. <br />12:00 <br />1' Ring <br />12:30 <br />1" Ring <br />30 min. <br />0 change <br />0.005 inches in %z <br />hour <br />® Pass ❑ Fail <br />® Yes ❑ No ❑ NA <br />N Yes ❑ No ❑ NA I ®Yes []No U NA I ®Yes ❑ No DNA I ® Yes ❑ No ❑ NA <br />Comments (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to a_y of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to gpy of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.