My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 1992
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
INSTALL 1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2019 4:40:15 PM
Creation date
8/23/2019 3:54:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1992
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
of hardcopy accountability of monitor status and EPA Failure to comply with these warnings could <br /> required inventory reports. result in serious personal injury,property loss and <br /> The Series X76 LVC portion is designed to monitor liq- equipment damage. <br /> uid level, vapor density, pressure and hydrostatic 3.1 Probe Riser Pipe Installation <br /> pressure. The system gererates an alarm and may <br /> shut down specific facilities if preset parameters are See Installation Drawing for dimensions and in- <br /> exceeded. The microprocessor based system stallation requirements. <br /> provides visual and audible alarms, self-diasgnostics A. For maximum height to volume conversion ac- <br /> and sensor failure indication, fail-safe shutdown and curacy, use one of the threaded bushings <br /> auxiliary switch outputs for communications to a closest to the center of the tank and install a <br /> facility's remote displays. 4" riser pipe (Ansi pipe Sch. 40). The top end <br /> The liquid level sensors will indicate presence of of the riser pipe should be threaded to accept <br /> liquids in the annular space of double-wall tanks, a four inch N.P.T., an 950 adapter, and a 950 <br /> secondary containment pipes, manhole of caisson locking cap with watertight cable grip, which <br /> compartments and in-tank high level to prevent over- are supplied with the probe. Insert a 4" <br /> fill. diameter riser pipe; install adaptor and cap. <br /> The vapor density, measured by the product's unique B. If the tank is buried, excavate the portion con- <br /> vapor transducer, is indicated on the appropriate plug- taining the tank hole to be used. Remove the <br /> in module in parts per million (ppm) by means of a 4 plug from the hole and insert the riser pipe as <br /> 1/2 digit LED display. The display not only indicates described above. <br /> the initial background vapor density in a vadose well Note: Be sure there is enough clearance be- <br /> or the annulus of any secondarily contained vessel, tween the top of the riser and the bottom of the <br /> but also monitors an increasing trend of vapor den- manhole cover to allow room for the two-wire <br /> sity. The self-contained display also provides the cable supplied with the probe. <br /> ability to set the alarm and shutdown setpoints <br /> without additional calibration equipment. 3.2 Manhole Installation <br /> The pressure measurement utilized to monitor pres- Install an #987 square manhole at each probe <br /> surized supply piping reads the pressure decay location. Offsetting the probe riser will allow <br /> caused by a leak rate greater than 0.05 GPH occur- added ease in junction box installation. <br /> ring between automatic test cycles (every 30 minutes). 3.3 Conduit Location <br /> A hydrostatic measurement is applied to the annulus <br /> of a double-wall tank by detecting a loss of pressure WARNING: Probe to controller conduit must <br /> in the pressurized cavity or the loss of liquid level in a not exceed 2,500 feet. See Installation <br /> reservoir or the annulus of the tank. Diagram cable notes for proper wiring re- <br /> quirements. Runs over 2,500 feet are not U.L. <br /> The X76 ETM System, housed in an attractive wall approved for this application. Refer to the <br /> mounted NEMA Type 1 Enclosure, contains the intrin- X76 LVC Installation and Operating manual <br /> sically safe barrier interface to the transducer, a num- for sensor limitations. <br /> ber of three channel alarm modules, vapor modules, <br /> and/or dispenser modules. The front door mounted WARNING: Explosion may occur if the con- <br /> audible alarm and the flashing alarm lights are ac- troller is installed in a volatile, combustible or <br /> knowledged by the ACK button and functionally explosive atmosphere. <br /> tested by means of the TEST push button. Failure to comply with these warnings could <br /> result in serious personal injury, property loss <br /> and equipment damage. <br /> (Refer To Installation Drawing) <br /> 3.0 SITE PREPARATION A. Select a mounting location on the inside wall <br /> of an enclosed building that allows easy ac- <br /> WARNING:Take necessary precautions to cess to the controller. When selecting a loca- <br /> prohibit vehicles from entering the working area tion, consider the entry path of the probe wire <br /> during installation or service. conduit from the underground tanks to the con- <br /> troller. The controller should be located with <br /> WARNING: During installation and use of this the LCD at eye level. <br /> product, comply with the National Electrical Code, <br /> federal, state and local codes, and any other ap- B. Run a 3/4" rigid metal conduit between the <br /> plicable safety codes. breaker box and the X76 ETM controller for <br /> the power wire input. If a plug connector is <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.