Laserfiche WebLink
The maximum average daily flow for the Site was estimated to be 766.2 gallons per day <br /> (gpd). Through the use of a weighted average, the average concentration of all the <br /> different effluent flows and concentrations was determined to be 47.4 mg/L-N at 766.2 <br /> gallons per day. Please see the following tables that present the information in a <br /> tabular form. <br /> Table 4. Average Daily Flow Calculation <br /> Use Units Rate Subtotal Reduction Average Daily <br /> Flow <br /> Existing 4 bed 120 gal/bdday 360 gpd None 480 gallons per <br /> Residence rooms day <br /> Potential <br /> Future 2 bed 120 gal/br/day 240 gpd None 240 gallons per <br /> Second rooms day <br /> Dwelling Unit <br /> Winery <br /> Customers 20 cust 5 gal/cust 100 gpd 3/7 42.8 gallons per <br /> (3 days) day <br /> Winery StaffVExcluded because staff members live on-site <br /> Event 2.7 gallons per <br /> Customers 40 cust 5 gal/cust 200 gpd 5/365 day <br /> (5X per year) <br /> Special <br /> Event Staff 4 staff 13 gal/staff 52 gpd 5/365 0.71 gallons per <br /> day <br /> (5X per year) <br /> Reduction factors convert calculated flow into average daily flow over a year. This needs to be taken into account <br /> since the winery is only open three days per week, and special events only take place periodically. No reduction is <br /> used for a residence since it is continuously occupied. <br /> LOGE 1122 Page 11 <br />