My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0005041
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GATEWAY
>
25521
>
2600 - Land Use Program
>
PA-0500269
>
SU0005041
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:31:26 AM
Creation date
9/5/2019 10:39:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0005041
PE
2622
FACILITY_NAME
PA-0500269
STREET_NUMBER
25521
Direction
S
STREET_NAME
GATEWAY
STREET_TYPE
BLVD
City
TRACY
APN
20942023
ENTERED_DATE
5/13/2005 12:00:00 AM
SITE_LOCATION
25521 S GATEWAY BLVD
RECEIVED_DATE
5/10/2005 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\G\GATEWAY\25521\PA-0500269\SU0005041\APPL.PDF \MIGRATIONS\G\GATEWAY\25521\PA-0500269\SU0005041\CDD OK.PDF \MIGRATIONS\G\GATEWAY\25521\PA-0500269\SU0005041\EH COND.PDF \MIGRATIONS\G\GATEWAY\25521\PA-0500269\SU0005041\MISC.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
151
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ProLogis Pond,Robinson&Associates,LP <br /> Patterson Pass Business Park#6-Tracy,CA Project No.051928 <br /> February 2005 Page 11 <br /> SECTION 3.0—Property Checklist <br /> Item Comments Condit <br /> Building Structure <br /> PML A Probable Maximum Loss(PML)or seismic study completed for this Good <br /> project by Robert D.Boyens Engineering estimated a Project PML of 13% <br /> of building value. <br /> Foundation Structural drawings reviewed on site for adjacent buildings indicated that Good <br /> the buildings in the Business Park are supported by reinforced concrete <br /> spread footings designed for an allowable soil bearing of 2,000 psf. No <br /> significant foundation distress was observed or reported. No geotechnical <br /> report was provided for our review. <br /> Framing System(s) The framing system consists of approximately 30-foot tall,T/4-inch Good <br /> structural thickness,perimeter load-bearing,concrete tilt-up wall panels <br /> and square steel tube interior columns,steel girders and 36-to 32-inch deep <br /> open web steel joists supporting 2"by 6"timber sub-purlins with V2-inch <br /> thick oriented strand board(OSB)roof deck.Steel framing includes bolted <br /> and welded connections. Bay spacings are typically 40 feet and 50 feet in <br /> the east-west direction and approximately 35 feet in the north-south <br /> direction. The structure provides a minimum interior clear height of <br /> approximately 24 feet within the building.No structural design loading <br /> information was provided. <br /> On-Grade Floor According to the structural drawings for similar buildings within the Good <br /> Structure business park,the on-grade floor structure in the main warehouse areas is <br /> expected to consist of a 6-inch thick cast-in-place concrete slab-on-grade <br /> reinforced with No.4 reinforcing steel bars placed at 24-inch intervals each <br /> way over a 6-inch aggregate base and 18 inches of compacted fill. <br /> Construction joints are located at regular intervals in each direction, <br /> typically aligned with the column grid. Typical shrinkage cracks and a few <br /> other minor cracks were observed in the slab.No differential settlement or <br /> heaving was observed at the cracks. No evidence of slab curling was <br /> observed. <br /> Upper Level Floor Not applicable to this facility. N/A <br /> Structure <br /> Roof Structure& The roof deck consists of%:-inch oriented strand board(OSB)wood Good <br /> Decking decking on 2x6 timber sub-purlins supported by steel open web joists. No <br /> active leaks were observed or reported by the tenants. The roof has a built- <br /> up roof system which typically has a 15-year life span and is not expected <br /> to require replacement during the evaluation term. <br /> [Expansion <br /> ecks&Balconies Not applicable to this facility. N/A <br /> tructural Structural expansion is allowed at the exterior wall panel-to-panel joints. Good <br /> Joints Otherwise,no structural expansion joints were provided. No evidence of <br /> obvious and large differential settlements,movement or distress was <br /> observed in the structural anels. <br /> ir Structure Not a licable to this facili . N/A <br /> ailing&Guard Handrails are utilized at exterior ramps and consist of painted steel pipe. Good <br /> ails <br /> Parkin Structure Notapplicable to this facility. N/A <br /> C ort Structure Not applicable to this facility. N/A <br /> E ui ment Supports I Prefabricated metal curbs support the rooftop HVAC units and sk li hts. Good <br />
The URL can be used to link to this page
Your browser does not support the video tag.