Laserfiche WebLink
ProLogis Pond,Robinson&Associates,LP <br /> Patterson Pass Business Park#6-Tracy,CA Project No.051928 <br /> February 2005 Page 15 <br /> SECTION 3.0—Property Checklist <br /> Item Comments Condition <br /> Fire&Life Safety Systems <br /> Fire-Rated The construction drawings provided for our review identified the type of Good <br /> Construction fire rated construction to be Type III-N,according to the 1997 Uniform <br /> Building Code. The entire facility is protected by an ESFR wet fire <br /> sprinkler system with three risers. The sprinkler system is supported by <br /> city water supply,fire pump and controller located in a pump room <br /> attached to an adjacent building. The fire pump serves three buildings in <br /> the complex. <br /> Means of Egress Multiple exits from the regularly spaced personnel and loading dock doors Good <br /> from the warehouse areas are provided. Hard-wired exit lights and <br /> emergency lights with battery back up are provided and most were <br /> observed to he in good working condition. We recommend that the exit <br /> lights and emergency lights be tested regularly. <br /> Fire Sprinkler The building is fully protected by an ESFR automatic wet fire sprinkler Good <br /> System system designed with multiple risers and pendant and upright style <br /> sprinkler heads. Tags on the system indicate that the system was designed <br /> by CEN-CAL Fire Systems,Inc of Lodi,California <br /> Placards indicate the following designs for each of the risers: <br /> System Design Criteria Riser Riser Riser <br /> III IV V <br /> Riser diameter,in. 8 8 8 <br /> No.of sprinklers 21 21 21 <br /> Density, m/SF 0.495 0.495 0.495 <br /> Area,SF 2000 2000 2000 <br /> System Demand <br /> Flow Rate,gpm 1045.5 1045.5 1045.5 <br /> Pressure,psi 57.9 57.9 57.9 <br /> The systems for the subject building and two adjacent existing buildings is <br /> pressurized by a 110 hp Patterson diesel engine fire pump and a 1/2 hp <br /> jockey pump with Firetrol,Inc and Hubbell/Industrial controller, <br /> respectively. The fire sprinklers identified at the site are not part of the <br /> product recall program initiated by Central. The system was last inspected <br /> and tested in September of 2004 by Delta Fire Systems. We recommend <br /> continuing regular fire sprinkler system inspection and testing. <br /> The test reports provided indicate that the system was inspected and tested <br /> on January 21,2003 by Standard Fire Protection and the pump was tested <br /> on the same date by George E.Swett&Co.,Inc.A five year tag on the <br /> system in the pump room indicates that the system was tested by Standard <br /> Fire Protection in January 2002. From the information provided we <br /> anticipate that the system and fire pump are due for annual inspection and <br /> we recommend continuing regular fire sprinkler system inspection and <br /> testing. <br />