My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011318
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HOLLY
>
20500
>
2600 - Land Use Program
>
PA-1700072
>
SU0011318
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2022 11:59:44 AM
Creation date
9/5/2019 11:18:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0011318
PE
2633
FACILITY_NAME
PA-1700072
STREET_NUMBER
20500
Direction
S
STREET_NAME
HOLLY
STREET_TYPE
DR
City
TRACY
Zip
95304-
APN
21216010
ENTERED_DATE
4/17/2017 12:00:00 AM
SITE_LOCATION
20500 S HOLLY DR
RECEIVED_DATE
4/17/2017 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Supplemental fields
FilePath
\MIGRATIONS\H\HOLLY\20500\PA-1700072\SU0011318\APPL.PDF \MIGRATIONS\H\HOLLY\20500\PA-1700072\SU0011318\CDD OK.PDF \MIGRATIONS\H\HOLLY\20500\PA-1700072\SU0011318\EHD COND.PDF \MIGRATIONS\H\HOLLY\20500\PA-1700072\SU0011318\MISC.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
16. Separate the hydrant loop from the sprinkler service such that pressurization of any FDC <br /> Fire Department Connection does not result in pressurization of the hydrant loop. <br /> 17. FDC's and Fire hydrants shall be located outside the collapse zone of the exterior wall. <br /> 1.5 times the height of the wall minimum. <br /> 18. A hydrant shall be located no further than 100'from an FDC. <br /> 19. Fire service lines shall be arranged such that there are no more than 6 appurtenances <br /> between isolation valves per NFPA 24 <br /> 20. Provide a fire hydrant loo . <br /> 21. Automatic gates shall be UL 325 listed and constructed and installed per ASTMF2200. <br /> 2016 CA Fire Code Section 503.5. <br /> 22. Automatic gates shall be provided with an Opticom and knox switch on both sides of the <br /> gate allowing fire department entry without leaving the cab of the truck unless the <br /> access road is an exit loop. Manual gates shall be provided with knox key boxes on <br /> both sides of the gate. <br /> 23. For new construction, plans shall be submitted to the AHJ for determination of the <br /> minimum water supply required before construction is started. Provide calculations of <br /> the water supply and tank size. Our preliminary calculations indicated that the fire water <br /> to be provided by a 40' diameter tank would be insufficient according to the method used <br /> in NFPA 1142. This calculation was done as follows: <br /> Assumptions <br /> 1) Occupancy hazard estimate: Warehouses such as those for furniture, general <br /> storage, paint, paper, and woodworking industries-4. <br /> 2) Type of construction: Type 1116-1.0. <br /> 3) .Structure dimensions and volume: Area, 981,430 X Height 40=Volume <br /> 39,257,200 U. <br /> 4) Exposure hazard: None-0 <br /> Formula <br /> WS(min) (gal)= VS(tot) /OHC 4*CC 1.0 <br /> Where: <br /> WS (min) is the required water supply in gallons <br /> VS (tot) is the volume of the building <br /> OHC is the Occupancy Hazard Class <br /> CC is the Construction Classification Number <br /> Calculation <br /> WS=3925720014* 1.0= 9,814,300 gallons <br /> Reduction for sprinklers of 75% reduces water requirement to 2,453,575 gallons if ESFR <br /> sprinklers are installed. A 50% reduction in water supply is allowed for other type <br /> sprinklers resulting in water requirements of 4,907,150 gallons. <br /> .2,453,575 gallons 17.48 G/ft3 =328,018 ft3 of water (ESFR condition) <br /> 328,018 ft3 water/area of 40 foot diameter tank(1256 ft2)=261' high tank which is <br /> impractical. <br /> Conclusion, the size and/or number of water tanks intended to supply fire water <br /> are insufficient to provide the required volume of water for protection of a sprinklered <br /> building. Please supply your calculations and justification for the planned water volume <br /> and any assumptions you have made. This should be completed before the next <br /> submittal since it will affect civil engineering and site design. <br /> Plans Reviewed By: Robert Huff <br /> Phone: (209) 831-6412 <br /> Email: Robert.Huff@cityoftracy.org <br />