Laserfiche WebLink
L � � <br /> October 31, 2005 <br /> LNOA Project Number: E05132-A <br /> LSmall soil stains were observed in several locations on the subject property. <br /> • One domestic well and one septic system are located on the subject property. <br /> • Eleven transformers were observed along the subject property boundaries. Approximately half <br /> Lof these were not labeled PCB-free. <br /> 3.4 Past Off-Site Sources of Contamination <br /> LNo above-or below-ground potential or known sources of contamination to the subject property were <br /> identified from past uses of surrounding properties, except for the following: <br /> L. A 500-gallon underground storage tank for regular gasoline was reportedly located immediately <br /> adjacent to the east of the subject property from 1957 until its removal approximately five years <br /> Lago. The tank was removed without a permit. <br /> • Two former drug labs were identified within one-quarter mile of the subject property. Five <br /> additional hazardous materials incidents and one Local Oversight Program case were identified <br /> within one-quarter mile. <br /> • Marley Cooling Tower Company,located approximately one-half mile north-northwest of the <br /> subject property,has contaminated groundwater in the area with total chromium and hexavalent <br /> chromium. Hexavalent chromium has been detected in a monitoring well located in the Main <br /> Street roadway directly south of the subject property at 9.5 parts per billion (ppb) and in a <br /> domestic well to the south of this at 1.4 ppb. <br /> 3.5 Current Off-Site Sources of Contamination <br /> No above-or below-ground potential or known sources of contamination to the subject property were <br /> i <br /> identified from current uses of the surrounding properties, except for the following: <br /> V <br /> • A wooden debris pile,an above-ground storage tank,and a PVC pipe discharging water to the <br /> ground were observed on the adjacent property to the east of the subject property. <br /> L <br /> 4.0 EVALUATION OF IDENTIFIED CONTAMINATION SOURCES <br /> L, Agricultural chemical residues may remain on the property. No evidence was found, however, to <br /> indicate that the chemicals were applied inappropriately. <br /> LUnderground infrastructure may exist on the subject property in the vicinity of the former structures. <br /> Agricultural infrastructure may exist from the former farming operations. <br /> V <br /> I1 <br /> L <br /> L <br />