MONITORING AND RL.ORTING PROGRAM NO. 5-01-057 .J ; <br /> WOODBRIDGE PARTNERS INC. <br /> VICTOR FINE FOODS FACILITY <br /> FOR CLOSURE OF SURFACE IMPOUNDMENTS AND INJECTION WELL <br /> SAN JOAQUIN COUNTY <br /> Each monitoring well shall be purged three times its well volume or until dry prior to sampling. <br /> Metal analysis shall be reported as dissolved (filter). The Discharger is required to perform <br /> sampling, analysis, and observations according to the schedule in Table 2. <br /> Table 2 - Groundwater Monitoring <br /> Parameters Units Frequency <br /> Field Parameter <br /> Groundwater Elevation Ft.,&hundredths, MSL Semi-annually <br /> Temperature °C Semi-annually <br /> Specific Conductance un-flios/cin Semi-annually <br /> pH pH number Semi-annually <br /> Monitoring Parameters <br /> Total Dissolved Solids mg/L Semi-annually <br /> TPH-gasoline mgt Semi-annually <br /> TPH-diesel mgt Semi-annually <br /> Volatile Organic Compounds ug/L Semi-annually <br /> (EPA Method 8260,see Attachment C) <br /> Bicarbonate Alkalinity mgt Semi-annually <br /> Chloride mg/L Semi-annually <br /> SSemi-annually <br /> Sulfate mg/L <br /> Nitrate-Nitrogen mgSemi-annually <br /> t <br /> CSemi-annually <br /> Calcium mg/L <br /> t Semi-annually <br /> Magnesium mg <br /> Semi-annually <br /> Potassium mg/L <br /> Semi-annually <br /> Sodium mg/L <br /> 4. LCRS Monitoring <br /> These WDRs require closure of Pond 1 and removal of Pond 1's Leachate Collection and <br /> Recovery System (LCRS). Until the Pond 1 LCRS is removed it will be sampled for the <br /> following: <br />