Laserfiche WebLink
3.6 Discussion of General Area Septic Tank Repair History: Repair history of the septic <br /> tanks in this area reveals that the leach lines and seepage pits have resulted in consistent unerring <br /> performance. This is based on the fact that no septic system repair application has been applied <br /> for. <br /> 3.7 Description of Proposed or Expected Maximum (including second unit dwellings) septic <br /> tank usage on site. The homesite parcel will have only a primary residence, no second unit <br /> dwellings are planned, thus only one septic system is anticipated at this time. Per County <br /> ordinances, each parcel on this map is entitled to one primary residence and one second unit <br /> dwelling. Therefore this project could ultimately have 2 homes on the one proposed homesite <br /> parcel. <br /> 4.0 GROUNDWATER INFORMATION SECTION: <br /> 4.1 Description of the depth and gradient of groundwater in the general area: The depth to <br /> ground water in this area is approximately 110 feet according to the map of"Lines of Equal <br /> Depth to Groundwater" published Spring, 1999, by the San Joaquin County Flood Control and <br /> Water Conservation District. The gradient descends from east to west. <br /> 4.2 Description/Discussion of any existing and/or potential groundwater contamination <br /> issues in the general location of the site: The concerns for groundwater contamination in this <br /> area is deemed low due to the depths involved. Insecticides, pesticides, and fertilizers typically <br /> do not impact groundwater at these depths, however, as with any agricultural area, there is <br /> always potential for contamination due to chemicals used in the farming operation. <br /> 4.3 Description of location, type and construction of well and location where water <br /> sample(s) were obtained: Water samples were taken from a spigot at the house located at <br /> 5250 Van Allen Road on April 29, 2005 by Louie Mendez of Dillon & Murphy. The water <br /> samples were obtained at this location due to the fact there are no outlets for water on the <br /> project site. The sample site is adjacent to the project site. <br /> 4.4 Description of constituents being tested for in the water sample: The water samples <br /> are being tested for nitrates and DBCP. The results for dibromochloropropane (DBCP) were <br /> non-detected and the results for nitrates were 8.81 mg/L. <br /> 4.5 Description of how sample was obtained, handled, stored, and transported to the lab: <br /> The water samples were obtained from the spigot at the house located 5250 Van Allen Road. <br /> The samples were taken by Louie Mendez of Dillon & Murphy, and driven directly to Precision <br /> Enviro-Tech. The samples were taken and handled in accordance with Precision Enviro-Tech <br /> requirements. The results from the test can be found in the Appendix. <br /> 4.6 Complete Chain of Custody document, including printed and signed name of third <br /> party sampler, condition of sample and date and time the sample was submitted to the lab. <br /> For Laboratory samplers, complete laboratory report to include the above noted <br /> information: The complete chain of custody document is located in the Appendix. <br /> 2 <br /> c:\0362\Soil Report 050405 <br />