My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011185
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WAUDMAN
>
1927
>
2600 - Land Use Program
>
PA-1600263
>
SU0011185
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:01 AM
Creation date
9/9/2019 11:03:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0011185
PE
2632
FACILITY_NAME
PA-1600263
STREET_NUMBER
1927
Direction
W
STREET_NAME
WAUDMAN
STREET_TYPE
AVE
City
STOCKTON
Zip
95209-
APN
08029039
ENTERED_DATE
1/13/2017 12:00:00 AM
SITE_LOCATION
1927 W WAUDMAN AVE
RECEIVED_DATE
1/13/2017 12:00:00 AM
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WAUDMAN\1927\PA-1600263\SU0011185\APPL.PDF \MIGRATIONS\W\WAUDMAN\1927\PA-1600263\SU0011185\CDD OK.PDF \MIGRATIONS\W\WAUDMAN\1927\PA-1600263\SU0011185\EHD COND.PDF \MIGRATIONS\W\WAUDMAN\1927\PA-1600263\SU0011185\EHD PERM.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(2) The required plans must be complete at the time of submittal for a building permit. <br /> Plans must address building design and construction, fire and life safety requirements, <br /> accessibility and show compliance with the current California codes and San Joaquin <br /> County ordinances. A complete set of plans must include fire sprinkler plans, truss <br /> calculations, energy calculations, plumbing, electrical and mechanical drawings as well <br /> as structural calculations. <br /> (3) A grading permit will be required for this project. Submit plans and grading <br /> calculations, including a statement of the estimated quantities of excavation and fill, <br /> prepared by a Registered Design Professional. The grading plan shall show the existing <br /> grade and finished grade in contour intervals of sufficient clarity to indicate the nature <br /> and extent of the work and show in detail that it complies with the requirements of the <br /> code. The plans shall show the existing grade on adjoining properties insufficient detail <br /> to identify how grade changes will conform to the requirements of the code. <br /> (4) A soils report is required pursuant to Section 1803 for foundations and appendix Section <br /> J104 for grading of the CBC. All recommendations of the Soils Report shall be <br /> incorporated into the construction drawings. <br /> (5) For each proposed building,provide the following information on the plans: <br /> A. Description of proposed use <br /> B. Existing and proposed occupancy Groups <br /> C. Type of construction <br /> D. Sprinklers(Yes or No <br /> E. Number of stories <br /> F. Building height <br /> G. Allowable floor area <br /> H. Proposed floor area <br /> I. Occupant load based on the CBC <br /> (6) Accessible routes shall be provided per CBC Section 11B-206. At least one accessible <br /> route shall be provided within the site from accessible parking spaces and accessible <br /> passenger loading zones;public streets and sidewalks; and public transportation stops to <br /> the accessible building or facility entrance they serve. Where more than one route is <br /> provided, all routes must be accessible. §11B-206.2.1 <br /> (7) At least one accessible route shall connect accessible buildings, accessible facilities, <br /> accessible elements, and accessible spaces that are on the same site. §11B-206.2.2 <br /> (8) Parking spaces will be required to accommodate persons with disability in compliance <br /> with Chapter IIB of the California Building Code, including van accessible spaces. <br /> These parking space(s) shall be located as close as possible to the primary entrance to <br /> the building. <br /> (9) Adequate sanitary facilities shall be provided for the facility, per the requirements of <br />
The URL can be used to link to this page
Your browser does not support the video tag.