3.7 Description of Proposed or Expected Maximum (including second unit dwellings) septic <br /> tank usage on site. There are two homes on site with existing septic systems. In the near future <br /> a new home will be constructed on Parcel 1. However, each parcel is entitled to a primary residence <br /> — and a second unit dwelling. Any new systems must be constructed under a permit. �� <br /> 4.0 GROUNDWATER INFORMATION SECTION: <br /> — <br /> 4.1 Description of the depth and gradient of groundwater in the general area: The depth to <br /> ground water in this area is approximately 120 feet according to the map of"Lines of Equal Depth <br /> to Groundwater" published Spring, 2013, by the San Joaquin County Public Works Department of ( �, <br /> Water Resources. The gradient descends from east to west. <br /> 4.2 Description/Discussion of any existing and/or potential groundwater contamination issues <br /> in the general location of the site: The concerns for groundwater contamination in this area are <br /> deemed moderate due to the depths involved. Types of activity in the area include crop fertilization, <br /> pesticides and other chemicals used to protect the products. Insecticides, pesticides, and fertilizers <br /> typically do not significantly impact groundwater at these depths. However, as with any agricultural <br /> area, there is always potential for contamination due to chemicals and types of production in farming <br /> operations. <br /> 4.3 Description of location, type and construction of well and location where water sample(s) <br /> were obtained: Water samples were taken from a faucet on a domestic well located on the property in <br /> question, 29892 E. Wimer Road on April 9, 2014 by Mike Toy of Dillon& Murphy. <br /> _ 4.4 Description of constituents being tested for in the water sample: The water samples are being <br /> tested for nitrates and DBCP. (4(-'o <br /> 4.5 Description of how sample was obtained, handled, stored, and transported to the lab: <br /> The water samples were obtained from a faucet at the domestic well located at 29892 E. Wimer Road. <br /> — The samples were taken by Mike Toy of Dillon & Murphy, and driven directly to Precision Enviro-Tech. 6�SJ <br /> The samples were taken and handled in accordance with Precision Enviro-Tech requirements. The results <br /> from the test can be found in the appendix. <br /> 4.6 Complete Chain of Custody document, including printed and signed name of third party <br /> sampler, condition of sample and date and time the sample was submitted to the lab. For <br /> Laboratory samplers, complete laboratory report to include the above noted information: <br /> The complete chain of custody document is located in the Appendix. No <br /> 5.0 SOIL PROFILE INFORMATION SECTION: <br /> — 5.1 Site map showing location,with dimensions, of the soil profile pit on the parcel: (See <br /> Appendix.) <br /> 5.2 Description of soil profile pit including depth and dimensions: The shallow test hole was <br /> prepared per County Standards. The hole was excavated to a depth of 42 inches and 8 inches in <br /> diameter. It was backfilled with 2 inches of"pea gravel." l �/ <br /> 2 <br /> — Y:0MDOC\2014\1414\SSS April 2014.doc <br />